Brooks Automation
278580 Revision A
131
LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.3 Operation of SECS Protocol
Host requests reader attributes with S18F1
Host to Reader: S18F1
15:19:31 Outgoing: ENQ ( 05 )
15:19:31 Incoming: EOT ( 04 )
15:19:31 Outgoing: Length Byte ( 5A )
15:19:31 Outgoing: Header ( 01 FF 92 01 80 01 00 00 00 03 )
15:19:31 Outgoing: Data (
01 02
41 04 31 32 33 34
01 04
41 0D 43 6F 6E 66 69 67 75 72 61 74 69 6F 6E
41 0B 41 6C 61 72 6D 53 74 61 74 75 73
41 11 4F 70 65 72 61 74 69 6F 6E 61 6C 53 74 61 74 75 73
41 15 53 6F 66 74 77 61 72 65 52 65 76 69 73 69 6F 6E 4C 65 76
65 6C )
15:19:31 Outgoing: Checksum ( CD 02 )
15:19:31 Incoming: ACK ( 06 )
Reader to Host: S18F2
15:19:31 Incoming: ENQ ( 05 )
15:19:31 Outgoing: EOT ( 04 )
15:19:31 Incoming: Length Byte ( 44 )
15:19:31 Incoming: Header ( 81 FF 12 02 80 01 00 00 00 03 )
15:19:31 Incoming: Data
01 04
41 04 31 32 33 34
→
TARGETID "1234"
41 02 4E 4F
→
SSACK "NO"
01 04
41 02 30 31
→
Configuration "01"
41 01 30
→
Alarmstatus "0"
41 04 49 44 4C 45'
→
OperationalStatus "IDLE"
41 06 56 31 2E 30 2E 30
→
SoftwareRevision Level
01 04
→
STATUS <L4>
41 02 4E 45
→
PMInformation "NE"
41 01 30
→
Alarmstatus "0"
41 04 49 44 4C 45
→
OperationalStatus "IDLE"
41 04 49 44 4C 45
→
HeadStatus "IDLE"
15:19:31 Incoming: Checksum ( 0C 29 )
15:19:31 Outgoing: ACK ( 06 )
The host requests all fundamental CIDRW attributes defined in ATTRID.
The reader answers with the actual attribute values.