Brooks Automation
278580 Revision A
61
LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.2 Operation of the ASC-I1 Protocol
Time between two read or write attempts.
01 .. 99 (0.1 s)
Default: 05 (0.5 s)
Parameter 4 (0x04)
r/w max repeat
Maximum number of read/write attempts.
01 .. 99
Default: 05
Parameter 5 (0x05)
RS232 repeat time
In case no confirmation message from the host was received, the device
waits this time before sending again the message to be confirmed. The
number of repeats is defined in
Î
Parameter 6 (0x06).
01.. 99 (0.1 s)
Default: 45 (4.5 s)
Parameter 6 (0x06)
RS232 max repeat
If the host does not send the expected confirmation message, the device
repeats the message according the value of this parameter. After that, an
error message is sent.
00
- never ending
01 .. 99 - number of attempts
Default: 3
Parameter 7 (0x07)
Watch port
Enables/disables the event message to the host that the floating contact
(external input) was opened.
00
- not activated (no event message)
01 -
activated
Default: 1