Brooks Automation
38
278580 Revision A
6 Installation
LF80C ZeniD RFID Reader
6.8 Ethernet Connection
Product Manual
6 . 8
E t h e r n e t C o n n e c t i o n
The 10/100 BaseT Ethernet interface has the following default settings:
DHCP mode
OFF
IP address
10.73.254.211
Gateway address
10.73.254.254
Subnet mask
255.255.254.0
If DHCP is enabled and the DHCP Server is not available, the device
initializes the Ethernet connection with the following values:
IP address
169.254.MAC5.MAC6
Gateway
169.254.MAC5.254
Subnet mask
255.255.255.0
Primary DNS Server IP
0.0.0.0
Secondary DNS Server I
0.0.0.0
(MAC address
MAC1:MAC2:MAC3:MAC4:MAC5:MAC6)
The Brooks Device Discoverer Tool can be used to find a device in the
network and to change the network settings easily. After sending a
configuration message, the tool requests the device configuration
password. Please enter the default password for Brooks RFID devices:
BROOKS
.
The tool can also be used to perform a firmware update!
ATTENTION
For more information our extensive download area is available to you at
www.brooks.com
-> Service -> Download.