LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.3 Operation of SECS Protocol
Parameter 33 (0x21)
Automatic antenna adjustment
The parameter defines the permitted causes for an antenna adjustment.
0
Automatic adjustment is not activated
1
Automatic adjustment only by Tuning button
2
Automatic adjustment only by external command
3
Automatic adjustment by Tuning button or external command
Default: (3) automatic antenna adjustment by Tuning button or external
command
Parameter 34 (0x22)
Sensor type for presence sensor
Type of sensor signal to start an automatic read.
0
Automatic read starts if sensor is covered
1
Automatic read starts if sensor is not covered
Default: (0) sensor is covered
Parameter 35 (0x23)
Special features
After a hardware reset, the reader offers an automatic read if the presence
sensor is covered.
bit 0:
value 0: Execute auto read after reset, if sensor is covered
value 1: Execute no auto read after reset, if sensor is covered
(default)
bit 1:
value 0: Execute a sensor triggered auto read (default)
value 1: Execute no sensor triggered auto read
bit 2:
without function
bit 3:
without function
bit 4:
The setting of the LEDs by S18F13 "SetLED" is prioritized
Default: 0x01 (0000 0001)
Parameter 36 (0x24)
Lock membrane keyboard
This parameter defines the key statuses of the membrane keyboard. If a bit
is set, it activates the specified button.
xxx0 0001
Tuning button is active in test mode
xxx0 0010
Tuning button is active in normal mode
xxx0 0100
Test button is active
xxx0 1000
Read button is active
xxx1 0000
Write button is active
Default: (0001 1111)