Brooks Automation
128
278580 Revision A
7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
The reader detects an unrecognized function and sends the
message S9F5.
Host to Reader: S1F3
19:54:43 Outgoing: ENQ ( 05 )
19:54:43 Incoming: EOT ( 04 )
19:54:43 Outgoing: Length Byte ( 0A )
19:54:43 Outgoing: Header ( 01 FF 81 03 80 01 00 00 00 06 )
19:54:43 Outgoing: Checksum ( 0B 02 )
19:54:43 Incoming: ACK ( 06 )
Reader to Host: S9F5
19:54:43 Incoming: ENQ ( 05 )
19:54:43 Outgoing: EOT ( 04 )
19:54:43 Incoming: Length Byte ( 16 )
19:54:43 Incoming: Header ( 81 FF 09 05 80 01 00 00 00 07 )
19:54:43 Incoming: Data ( 21 0A 01 FF 81 ) =>The wrong message
header
19:54:43 Incoming: Data ( 03 80 01 00 00 00 06 )
19:54:43 Incoming: Checksum ( 04 4C )
19:54:43 Outgoing: ACK ( 06 )
The function "3" is not part of the SECSII message set, so a S9F5 error