Brooks Automation
278580 Revision A
11
LF80C ZeniD RFID Reader
4 Safety Instructions
Product Manual
4.5 ESD Instructions
4 . 5
E S D I n s t r u c t i o n s
4 . 6
R e s i d u a l R i s k s
Even if all precautions have been taken, there may be unapparent residual
risks!
Adhering to the safety instructions, the intended use, and the product
manual as a whole can reduce residual risks!
CAUTION
Static electricity can damage electronic components in the device. All
persons installing or maintaining the device must be trained in ESD
protection.
ESD protective measures must be applied when opening the device.
Â
Disconnect the power supply prior to removing or adding
components.
Â
Discharge your body and all tools used prior to contacting
any components on the interior of the device!
Â
Touch electronically sensitive parts carefully and at the
corners!
DANGER
Risks from electric current
Electrical energy remains in lines, equipment and devices even when the
device is switched off.
Only allow qualified electricians to perform work on the electrical supply
system.
ATTENTION
Disconnect the device from the power supply system if active parts of
the device can be accessed by using tools. Access is only permitted for
authorized personnel.
Regularly check the electrical equipment of the device. Regularly check
all moving cables for damage within the scope of maintenance and
repairs.