Brooks Automation
278580 Revision A
101
LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.3 Operation of SECS Protocol
Parameter 41 (0x29)
Delay time between read cycles
The delay time between two reading cycles. It takes care of the reading
module lifetime.
To increase reading speed, set the delay time to zero. There is no restriction
when using a mini or micro antenna. If you use a frame or rod antenna, the
reading module will approach the boundary conditions. There is no problem
if you read only a few pages or if you have a break between two readings
(all pages). If you want to read all pages continuously without any break,
please use the default value.
00...20 50 ms
Default: (2) 100 ms
Parameter 42 (0x2A)
CarrierIDOffset
Defines the offset of the CID within the CID field (MID area -
Î
Parameter
37 (0x25)).
The valid value range depends on the value of the MID area and the value
of the CarrierIDLength.
Valid range
0 … maximum bytes of CID -1
Default: 0
Length cannot be larger than the length of the CID field.