278580 Revision A
7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
Host requests a reset with S18F13
Host to Reader: S18F13
11:45:34 Outgoing: ENQ ( 05 )
11:45:34 Incoming: EOT ( 04 )
11:45:34 Outgoing: Length Byte ( 1F )
11:45:34 Outgoing: Header ( 01 FF 92 0D 80 01 00 00 00 3F )
11:45:34 Outgoing: Data
01 03
41 04 31 32 33 34
→
TARGETID "1234"
41 05 52 65 73 65 74
→
SSCMD "Reset"
01 01
41 02 4D 54
→
CPVAL1 "MT"
11:45:34 Outgoing: Checksum ( A1 02 )
11:45:34 Incoming: ACK ( 06 )
Reader to Host: S18F14
11:45:34 Incoming: ENQ ( 05 )
11:45:34 Outgoing: EOT ( 04 )
11:45:34 Incoming: Length Byte ( 2D )
11:45:34 Incoming: Header ( 81 FF 12 0E 80 01 00 00 00 3F )
11:45:34 Incoming: Data
01 03
41 04 31 32 33 34
→
TARGETID "1234"
41 02 4E 4F
→
SSACK "NO"
01 01
01 04
→
STATUS <L4>
41 02 4E 45
→
PMInformation "NE"
41 01 30
→
Alarmstatus "0"
41 04 49 44 4C 45
→
OperationalStatus "IDLE"
41 04 49 44 4C 45
→
HeadStatus "IDLE"
11:45:34 Incoming: Checksum ( 08 68 )
11:45:34 Outgoing: ACK ( 06 )
Reset is an optional service used to reinitialize the reader. If reader
parameter 9 is unequal to 0x00, the reset causes a S1F1 "Are you there"
message from the reader.