Parameter 11 (0x0B)
ReaderID
The reader ID is a part of the device ID. In the message header, it
corresponds to the 7 LSB (last significant bits) of the "upper message ID".
00 .. 127
Default: 0x01
The BROOKS SECS-I reader works simultaneously as a gateway and a
reader (CIDRW with integrated head). Therefore the reader ID is
predefined as 0x01. Of course, the ID can be changed within the valid
scope.
Parameter 12 (0x0C)
HeadID
If you use a 2-byte TARGETID, this parameter corresponds to TARGETID.
00 .. 31
Default: 0x01
The head ID is predefined as 0x01. Of course, the ID can be changed within
the valid scope.
Parameter 20 (0c14)
Sensor delay for presence sensor
Delay time for sensor signal to start an automatic read.
0 .. 255 1/10 s
Default: (10) 1 s
Parameter 22 (0x16)
Sensor-triggered action for presence sensor
0:
Read all transponders
1:
Read page 1 of a multipage transponder
...
17:
Read page 17 of a multipage transponder
240:
Read a read/only transponder
241:
Read a read/write transponder
Default: (0) read all transponders
Parameter 23 (0x17)
Triggered read frequency
If a read/write error occurs, the triggered read frequency defines the time
between two attempts to read or write a transponder; or the read
frequency if there is a triggered read (no polling).
2 .. 10 from 1 s
Default: (5) 500 ms