7 Operation
LF80C ZeniD RFID Reader
7.3 Operation of SECS Protocol
Product Manual
Parameter 29 (0x1D)
Transponder load duration (read mode)
The time required to load a transponder during a read process.
The default value (50 ms) should not be changed.
00 .. 255 ms
Default: (50) 50 ms
Parameter 30 (0x1E)
r/w synchronize
Enables/disables reader synchronization. If synchronization is enabled, the
reader takes notice of interference or other active readers and synchronizes
the reading cycle.
00
…
Synchronization disabled
01
…
Synchronization enabled
Default: (01) enabled
Parameter 31 (0x1F)
Auto-adjust value (read mode)
The influence of interferences in the environment of the readers can be
minimized by using the automatic adjustment during the operation. If the
parameter is set to defined values (0x00 - 0x40), the reader starts the
adjustment.
In case of automatic adjustment, the reader requires up to two seconds.
During this time the reader cannot receive any serial data.
00 ... 0x3F
Range of manual adjustment (read mode only)
0x40
Start automatic adjustment (read and write mode)
Parameter 32 (0x20)
Auto-adjust value (write mode)
The influence of interferences in the environment of the readers can be
minimized by using the automatic adjustment during the operation. If the
parameter is set to defined values (0x00 - 0x40), the reader starts the
adjustment.
In the case of automatic adjustment, the reader requires up to two
seconds. During this time the reader cannot receive any serial data.
00 ... 0x3F
Range of manual adjustment (write mode only)
0x40
Start automatic adjustment (read and write mode)
IMPORTANT
Automatic adjustment changes the adjustment of the read and write
modes (
Î
Parameter 31 (0x1F) and
Î
Parameter 32 (0x20)).