Brooks Automation
278580 Revision A
41
LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.1 Operating Personnel
7
O p e r a t i o n
This chapter gives you an overview of the following topics:
Î
Operating Personnel
Î
Operation of the ASC-I1 Protocol
Î
Operation of SECS Protocol
7 . 1
O p e r a t i n g P e r s o n n e l
7 . 2
O p e r a t i o n o f t h e A S C - I 1 P r o t o c o l
7.2.1
Structure of the Communication Protocol
General remarks:
The communication is done with ASCII packages.
Each reader represents a RFID reader with an RS232 interface to
which an address from 0 to E can be assigned. When the reader is
delivered, the address is 0.
After each command to the reader, a defined response is sent. We
recommend waiting for this response before sending a new
command.
7.2.2
Package Contents
General remarks:
Each package includes a package header (three characters), a message
(two or more characters) and the end of the package (five characters).
CAUTION
The RFID Reader LF80C ZeniD is designed to be operated by specially
trained personnel only. If you have doubts about the required
qualifications, contact the manufacturer.
Operating the device without special training can result in damage to the
reader and/or connected devices.
Package header
Message
End of package