Brooks Automation
278580 Revision A
83
LF80C ZeniD RFID Reader
7 Operation
Product Manual
7.3 Operation of SECS Protocol
Head attribute definitions:
"HeadStatus" The
current
status
"IDLE" ... Reader in IDLE mode
"BUSY" ... Reader is busy
"NOOP" ... Not operating
"HeadID"
Head number 00-31 (2 digits)
"00" ... Reader 0
"31" ... Reader 31
Where used
S18F2, S18F3
Description
Status request value
"OP" ...
Operating status
"MT" ...
Maintenance status
Where used
S18F13
Description
A vector or string of unformatted data.
Multipage transponder
DATA area depends on the MID area,
can be page 1 - page 17
Read/write transponder
DATA correspond to 8 byte MID
Read/only transponder
DATA correspond to 8 byte MID
Where used
S18F6, S18F7
Description
Total bytes to be sent.
The DATALENGTH corresponds to the quantity of bytes that are to be read
or written.
The valid range depends on the length of the MID area (
Î
Parameter 37
(0x25)).
Where used
S18F5, S18F7
CPVAL
Format: A[]
DATA
Format: A[]
DATALENGTH
Format: U2