CHAPTER 15: CONFIGURATION FROM THE COMMAND LINE
# config -s config.portaccess.rule2.netmask=255.255.255.0
# config -s config.portaccess.rule2.port5=on
# config -s config.portaccess.total=2
The following command will synchronize the live system with the new configuration:
# config -r serialconfig
15.1.7 CASCADED PORTS
To add a new slave device with the following settings:
TABLE 15-6. SLAVE DEVICE SETTINGS
SETTING
VALUE
IP address or DNS name
192.168.0.153
Description
Office 42
Label
LES1716A
Number of ports
16
Issue the following commands:
# config -s config.cascade.slaves.slave1.address=192.168.0.153
# config -s "config.cascade.slaves.slave1.description=Office 42"
# config -s config.cascade.slaves.slave1.label=cm7116-5
# config -s config.cascade.slaves.slave1.ports=16
The total number of slaves must also be incremented. If this is the first slave being added, type:
# config -s config.cascade.slaves.total=1
Increment this value when adding more slaves.
NOTE: If a slave is added using the CLI, the master SSH public key will need to be manually copied to every slave device before
cascaded ports will work (see Chapter 5).
The following command will synchronize the live system with the new configuration:
# config -r cascade
15.1.8 UPS CONNECTIONS
MANAGED UPSES
Before adding a managed UPS, make sure that at least 1 port has been configured to run in “device mode,” and that the device is
set “ups.”