Check Save Auto-Response.
NOTE: Before configuring UPS checks in Auto-Response you first must configure the attached UPS.
8.2.4 UPS STATUS
To use the alert state of any attached UPS as the Auto-Response trigger event:
Click on UPS Status as the Check Condition.
Select the reported UPS State to trigger the Auto-Response (either On Battery or Low Battery).
The Auto-Response will resolve when the UPS state returns to the Online state.
Select which connected UPS Device to monitor.
Click Save Auto-Response.
NOTE: Before configuring UPS state checks in Auto-Response, the attached UPS must be configured.
8.2.5 SERIAL LOG-IN, SIGNAL OR PATTERN
To monitor serial ports and check for login/logout or pattern matches for Auto-Response triggers events:
Click on Serial Login/Logout as the Check Condition.
In the Serial Login/Logout Check menu, select Trigger on Login (to trigger when any user logs into the serial port) or Trigger on
Logout.
Specify Serial Port to perform check on.
Click on Serial Signal as the Check Condition.
The above two options can be set individually or together.
In the Serial Signal Check menu, select the Signal (CTS, DCD, DSR) to trigger the condition (either on serial signal change, or check
level).
Specify Serial Port to perform check on.
Click on Serial Pattern as the Check Condition.
The above two options can be set individually or together.
In the Serial Pattern Check menu, select the PCRE pattern to trigger on and the serial line (TX or RX) and Serial Port to pattern
check on.
CHAPTER 8: ALERTS, AUTO-RESPONSE AND LOGGING