CHAPTER 8: ALERTS, AUTO-RESPONSE AND LOGGING
FIGURE 8-17. CONSOLE SERVER SETTINGS SCREEN
8.6.3 IP SUBNET-BASED VLAN
The console server supports optional logging of access to and communications with network attached Hosts.
For each Host, when you set up the Permitted Services that are authorized to be used, you also must set up the level of logging that
is to be maintained for each service.
Specify the logging level that is to be maintained for that particular TCP/UDP port/service, on that particular Host:
TABLE 8-4. LOGGING LEVEL OPTIONS
LOGGING LEVEL
DESCRIPTION
0
Turns off logging for the selected TCP/UDP port to the selected Host.
1
Logs all connection events to the port
2
Logs all data transferred to and from the port.
Click Add.
Click Apply.
8.6.4 AUTO-RESPONSE EVENT LOGGING
Navigate to Alerts & Logging > Auto-Response.
In the Global Auto-Response Settings section, check the Log Events check box.
Click Save Settings.
8.6.5 POWER DEVICE LOGGING
The console server also logs access and communications with network attached hosts and maintain a history of the UPS and PDU