3.7
Upload/download via serial interface
The format for data transmission is 7-bit ASCII with even parity bit and
one stop bit. The transmission rate can be set to 1.2 kbauds, 9.6 kbauds,
19.2 kbauds or 38.4 kbauds.
Only available for
some unit variants;
see chapter 3.1.
The RS 485 interface can be used for networking up to 31 units.
Parameters and data records are read from/loaded into the controller.
NOTE
The ten position sets can be stored in the controller memory. This
memory area can be accessed directly by
Position sets via front panel,
Upload/download via serial interface,
Teach-in via front panel or
Teach-in via inputs/outputs.
Prerequisites:
–
Front panel operation inactive.
–
Motor at standstill.
–
No error active.
NOTE
The following parameters must have been set (see chapter 3.3.1):
– Operating mode with parameter P00 = 0 or P00 = 3 (for electronic gear)
– Network address with parameter P60 (for RS 232 always 1)
– Baud rate with parameter P61
1.
Deactivate the AUTOM input.
2.
If “run” is displayed in the status display, upload/download of par-
ameters and positions is enabled.
NOTE
The transmitted values are retained after switching off.
Reference documentation
Uploading and downloading is described in the separate On-line Com-
mand Processing and Upload/Download via Serial Interface documen-
tation.
Upload/
Download
Operation
3-22
WDP3-01X Ident. no.: 00441109760