2.4.8
Encoder interface
(OPT.2)
NOTE
The encoder interface is installed in adapter slot 22; see type plate.
Power is supplied independently of the power controller.
1.
Solder the litz wires to the connector as described below.
2.
Push the shield back and fix with a cable tie.
3.
Insert two threaded bolts (fig. 2-17) into the connector shell.
4.
Place the connector into the connector shell.
5.
Fasten the cable and the shield to the connector shell with screws,
providing for strain relief.
ATTENTION
Ensure good electrical contact between the shield and the con-
nector shell.
Connect the shield on both ends.
6.
Assemble the two parts of the connector shell with two screws.
7.
Fasten the connector to the front panel (item 22) with screws.
8.
Twist the encoder cable wires in pairs.
9.
Establish the connection on the motor end.
ATTENTION
When using 5 V encoders, –SENSE must be connected to 5VGND
and +SENSE to 5VDC on the encoder end of the cable.
NOTE
The encoder signal type (pulse/direction or A/B signals) and the internal
evaluation (single, double or quadruple) must be selected for an elec-
tronic gear with the P50 parameter; see chapter 3.3.1.
Fig. 2-17 Encoder connector
assembly – device end
22
OPT.2
Installation
WDP3-01X Ident. no.: 00441109760
2-21