3.3.4
Value display on
front panel
The actual position and the software version can be displayed.
With an Interbus-S interface, d99 can be used for activating the diag-
nostic function.
Available for all device variants
1.
Set AUTOM input inactive unless on-line command processing is
active.
2.
Select the value to be displayed:
Display
Meaning
d0.0
Actual position digits representing ones
d0.1
Actual position digits representing thousands
d0.2
Actual position digits representing millions
d10
Software version
d99
Interbus-S diagnostic function
The Interbus-S diagnostics is activated with the d99 function and indi-
cates the following four states:
U
Operating voltage
RC Interbus-S link o.k.
BA
Interbus-S transmission active
RD No other Interbus-S slave available
U RC BA RD
Operation
3-12
WDP3-01X Ident. no.: 00441109760