Interface
adapter slot
Device functions
OPT.1
OPT.2
Field bus
(e.g. IBS
or
PBDP)
Not
installed
On-line command processing via field
bus interface
–
Manual mode via inputs/outputs or
front panel
–
On-line command processing
The controller (slave) receives
commands from a master unit and
executes them immediately.
–
Parameter input via front panel
RS 422
–
Rotation monitoring, if parameter
P20 = 2 and P00
≠
3
–
Electronic gear,
Gear parameter input by on-line
command processing via field bus
Analog
(ANOZ)
Not
installed
Oscillator mode via analog interface
–
Oscillator mode via analog
±
10 V input
–
Manual mode via inputs/outputs
or front panel
–
Parameter input via front panel
RS 422
–
Rotation monitoring, if parameter
P20 = 2 and P00
≠
3
Not
installed
or
RS 232
or
RS 485
or
field bus
RS 422
Electronic gear via encoder interface
–
Electronic gear,
via encoder interface
–
Manual mode via inputs/outputs
or front panel
–
Parameter input via front panel or serial
interface or field bus
NOTE
The interfaces installed in the unit are indicated on the type plate. The
following abbreviations are used:
ANOZ
Analog interface
CAN
CAN-Bus interface
IBS
Interbus-S interface
PBDP
Profibus-DP interface
RS 232
Serial interface RS 232
LRS 422-IN
Encoder interface RS 422
RS 485 LS
Serial interface RS 485
RS 485 HS
Serial interface RS 485 for SUCONET
General description
WDP3-01X Ident. no.: 00441109760
1-3