RS 422 IN signal level (option)
Encoder interface
Short-circuit protected
Internal leakage resistance towards ground
1 Mohm
Maximum cable length
100 m
Wire cross-section
2 x 0.5 mm
2
and 10 x 0.25 mm
2
Shield connection
On both ends
Supply voltage output
5 VDC
±
5% (300 mA max.)
or
12 VDC, 10 VDC min./18 VDC max. (200 mA max.)
Protection and monitoring circuits: Power amplifier overtemperature,
short-circuit between motor leads (no ground fault protection),
undervoltage and overvoltage
Device protection
Type of protection
IP 20 acc. to EN 60529: 1991
Regulations
Insofar as the machinery corresponds to the machinery directive
89/392/EEC and the configuration meets the EMC test conditions
specified by BERGER LAHR, conformity with the machinery
directive is hereby certified.
Machinery directive
In a configuration which meets the EMC test conditions specified
by BERGER LAHR, conformity with the following standards
can be certified in accordance with the EMC directive 89/336/EEC:
EMC directive
Radio interference suppression
according to EN 50081-2: 1993
(when using a mains filter, see Accessories)
Static discharge
according to EN 60801-2: 1993, class 4
Burst
according to IEC 801-4: 1988, class 4
–
Use a BERGER LAHR motor lead.
Length of motor lead is 10 m.
BERGER LAHR
EMC test requirements
–
Insert a BERGER LAHR mains filter into the mains supply line.
–
Install the device into the control cabinet.
–
Use BERGER LAHR signal cables and wire them according
to the documentation.
–
Run signal, mains and motor cables separately (non-parallel) and
ensure a large surface area contact between the cable shield and
ground on both ends.
–
Install the mains filter directly at the device. If this is not possible, use
a shielded connection line (1 m max.) between filter and device.
–
Ensure a large surface area contact between filter, device and
ground (mount on a grounded metal plate or on control cabinet
rear panel, or use a ground strap).
Pursuant to the low-voltage equipment directive 73/23/EEC, the
products are in conformity with the following standards:
Low-voltage equipment directive
Protection class
1 acc. to prEN 50178: 1994
Overvoltage
Category III acc. to prEN 50178: 1994
Contamination
Grade 2 acc. to prEN 50178: 1994
General description
WDP3-01X Ident. no.: 00441109760
1-15