Figure 2-4 illustrates the wiring layout of the positioning controller with
the available interfaces.
Wiring layout
Communication between PC and positioning controller is effected either
through the RS 232 or RS 485 serial interface or the field bus interface
(e.g. Interbus-S), depending on the actual interface configuration.
NOTE
If the controller is provided with an RS 485 interface and the PC with an
RS 232 interface, an interface converter (e.g. MP 923, see chapter 6.2.3)
must be used.
NOTE
With an RS 485 interface, the MP 924 interface distributor can be used
for implementing a network (see chapter 6.2.4).
NOTE
With an RS 232 interface, networking is not possible.
NOTE
With an Interbus-S interface, the MP 927 Interbus-S interface adapter
must be used (see separate documentation).
NOTE
With a Profibus-DP interface, e.g. a bus terminal must be used.