NOTE
The output states and the rectification of malfunctions are described in
chapter 4.
Inputs:
Outputs:
AUTOM
Motor
START
STOP active
→
Eliminate fault
FUNCTION2
ACTIVE
FUNCTION1
NO_ERROR
1
1
0
1
1
1
1
1
0
1
1
1
0
1
1
1
1
1
1
0
DATA1 to
DATA8
valid
t
Setup time
≥
500
µ
s
Hold time
≥
500
µ
s
Start delay
≤
6 ms
1
3
1
2
2
3
Idle
Rotation
Fig. 3-7 Position processing
interrupt timing diagram
Operation
WDP3-01X Ident. no.: 00441109760
3-21