1.
Activate the AUTOM input.
2.
Apply a voltage to the ANA_IN input.
→
The motor rotates at the speed which is proportional to this
voltage.
NOTE
The INV_DIR input can be used for inverting the motor’s sense of
rotation.
3.
Deactivate the AUTOM input.
→
The motor is decelerated.
NOTE
The motor can be deenergized with the CURRENT_OFF signal. In this
state, it does not have any holding torque.
To quickly stop and resume a motor movement, use the STOP input.
a
Acceleration (can be set by parameter P02)
b
Braking ramp (can be set by parameter P74)
U
max.
Voltage at maximum speed with CW sense of
rotation (can be set by parameter P70)
-U
max.
Voltage at maximum speed with CCW sense of
rotation (can be set by parameter P71)
U
Zero
Zero window (can be set by parameter P72)
V
max.
Maximum speed (can be set by parameter P04)
ANA_IN
Motor
speed
+U
-U
V
max.
-V
AUTOM
Inputs:
U
U
t
t
t
t
max.
V
max.
U
Zero
U
max.
-U
Zero
-U
a
a
b
b
STOP
Fig. 3-11 Timing diagram for
oscillator mode via
analog interface
Operation
WDP3-01X Ident. no.: 00441109760
3-31