1.3
Technical data
1.3.1
Electrical data
Supply voltage, selectable
115 VAC
230 VAC to 240 VAC
Mains connection
Power loss
WDP3-014
60 W max.
WDP3-018
110 W max.
Mains frequency
50 to 60 Hz
Mains error protection
one period
Nominal power consumption
WDP3-014
3.6 A at 115 VAC
2.0 A at 230 VAC
WDP3-018
6.5 A at 115 VAC
3.5 A at 230 VAC
Starting current
maximum 70 A
General description
External fuse
6 A at 230 VAC
10 A at 115 VAC
(“K” characteristic)
NOTE
The devices may only be operated with fuse protection as specified
above.
If necessary, use r.c.c.b. protection according to DIN VDE 0664
part 1/10.85.
Supply voltage
20 VDC to 30 VDC
System supply
via signal interface
Power consumption
1 A max.
Ripple voltage
< 2 V
pp
NOTE
The 24 V voltage supply must meet the specifications of the DIN standard
VDE 0160 on safety extra-low voltage.
Phase current
WDP3-014
0.1 A to 2.5 A
WDP3-018
0.1 A to 6.8 A
Motor connection
No. of steps
1000 steps per revolution
Pulse rate
maximum 40 kHz
Motor voltage
3 x 325 VDC (connected to mains)
Motor cable (observe EN 60204 standard)
Length
maximum 50 m
Cross-section
≥
0.75 mm
2
at cable length
≤
30 m
≥
1.5 mm
2
at cable length > 30 m
Shield connection
On both ends
Leakage current (IEC60990)
Motor cable <5m : <10mA
Motor cable 5-50m : <50mA
1-12