OUTPUTS
Front Panel LED’s:
OK LED:
TX/RX LED:
Bypass LED:
Indicates when the 3500/42 is operating
properly.
Indicates when the 3500/42 is communicating
with other modules in the 3500 rack.
Indicates when the 3500/42 is in Bypass
Mode.
Buffered Transducer
Outputs:
The front of each monitor has one coaxial
connector for each channel. Each connector
is short circuit protected.
Output Impedance:
550
Ω
Transducer Supply Values:
-24 Vdc
Recorder:
+4 to +20 mA. Values are proportional to
monitor full scale. Individual recorder values
are provided for each channel. Monitor
operation is unaffected by short circuits on
recorder outputs.
Voltage Compliance
(current output):
0 to +12 Vdc range across load. Load
resistance is 0 to 600
Ω
.
Resolution:
0.3662
µ
A per bit
±
0.25 % error at room temperature
-0.66 to +0.70 % error over temperature
range updated rate 100 ms or less.