Maintenance
3500/42 Operation and Maintenance
98
.
100
µ
F
Proximitor®
Seismic I/O
Module
Radial Vibration Test Setup
Input Signal
Power Supply
Multimeter
Function Generator
Keyphasor®
Signal
The equipment shown in the dashed box is required for 1X
Amplitude and Phase, 2X Amplitude and Phase, Not 1X
Amplitude, and S
max
Amplitude.
Keyphasor Multiplier/Divider
40 k
Ω
Keyphasor®
I/O Module
-18
Vdc
The Test Equipment outputs should be floating relative to earth ground.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com