19–1
S E C T I O N 1 9
Zone Lists
(*81 Menu Mode)
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
About Zone List Menu Mode
♦
Zone List Displays
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About Zone List Menu Mode
While in Program mode, press
✱
81 to enter Zone List Menu mode.
Zone List Menu
mode is used to program zone lists for output devices that were previously programmed in
✱
80 Menu mode. Refer to the Programming Form worksheet (
✱
81) that programs the Zone
Lists for Output Devices.
Zone List Displays
Zone List No.
(00 = Quit)
01
Enter the Zone List Number
01
,
02
, or
03
to program (or
00
to end
these entries). Press [
✱
] to advance.
In the following displays, zone list 01 has been selected for
programming.
01 Enter Zn Num.
(00 = Quit)
00
Enter each zone number to add to the zone list by first entering the
zone number, then [
✱
] (for example, 01
✱
, 02
✱
, 03
✱
). After all zones
desired have been entered, press
00
to advance.
IMPORTANT:
Do not include fire zones in zone lists that are used to
STOP relay actions.
01 Del Zn List?
0 = No 1 = Yes
0
To delete the zone list, enter
1
(Yes). All zones in the zone list are
deleted automatically and programming returns to the first screen.
To save the zone list, enter
0
(No) to advance.
01 Delete Zone?
0 = No 1 = Yes
0
To save the entire zone list, enter
0
(No); programming returns to the
first screen.
To delete a zone or zones in a zone list, enter
1
(Yes) to advance.
01 Zn to Delete?
(00 = Quit)
00
Enter each zone to be deleted from the list, followed by [
✱
]. After all
zones to be deleted are entered, enter
00
to return to the first screen
so that another list can be programmed, if desired.
NOTES:
• Any list may include any or all of the system's zone numbers.
• A zone list can be assigned to more than one output relay.
Summary of Contents for Vista-20Bay
Page 2: ......
Page 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Page 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Page 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Page 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Page 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Page 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Page 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Page 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Page 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Page 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Page 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Page 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Page 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Page 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Page 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Page 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...