VISTA-20BAY Installation & Setup Guide
16–6
Pager Report Format
Entries 6 through 9 sends a report to a pager using the following format:
The pager report is formatted as follows:
AAAAAAAAAAAAAAAA
–
BBB
–
CCCC
where:
A
= (Optional.) Up to 16 digits for account numbers, PIN numbers, or any
additional data that will precede the 7-digit system status code BBB and
CCCC (see
B
and
C
below). This optional data is programmed in field
✱
88, Paging Characters.
B
= A 3-digit code that describes the event that has occurred in the system
(see the explanation below).
C
= A 4-digit user or zone number, depending on the type of event that has
occurred. For alarms or troubles, these digits represent the zone number.
For openings (disarming) and closings (arming), these digits represent
the user number. In this system, the first 2 digits will always be “00.”
Single-digit zone or user numbers are also preceded by a “0.”
The 3-digit Event codes (BBB) that can be sent are:
911
=
Alarms
. The 4-digit number (CCCC) that follows this code is the
zone number that has caused the alarm.
811
=
Troubles
. The 4-digit number (CCCC) that follows this code is the
zone number that has caused the trouble.
101
=
Open
(system disarmed). The 4-digit number (CCCC) that follows
this code is the User number.
102
=
Close
(system armed). The 4-digit number (CCCC) that follows this
code is the User number.
✱
50
15-SECOND DIALER DELAY (BURGLARY)
0
0 = no dialer delay
1 = provide 15-second delay of Burglary Alarm report (except zone type 24) to
the Central Station, which allows time for the subscriber to avoid a false
alarm transmission. This delay does
not
apply to zone type 06 (24-Hr Silent),
zone type 07 (24-Hr Audible), zone type 08 (24-Hr Aux) ), zone type 09 (Fire), and
zone type 24 (Silent Burglary), which are always sent as soon as they occur.
UL installations: Must be 0 (no delay)
✱
51
PERIODIC TEST REPORT
0
0 = no test report
1 = once every 24 hours
2 = weekly
3 = once every 30 days
Test Report Code entered in field
✱
64 is sent. Reports with Subscriber No.
✱
52
TEST REPORT OFFSET
2
0 = 24 hours after exiting program mode or download
1 = 6 hours after exiting program mode or download
2 = 12 hours after exiting program mode or download
3 = 18 hours after exiting program mode or download
This is the time from programming or downloading until first report.
Summary of Contents for Vista-20Bay
Page 2: ......
Page 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Page 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Page 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Page 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Page 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Page 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Page 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Page 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Page 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Page 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Page 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Page 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Page 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Page 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Page 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Page 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...