Section 4 - Basic Hardwired Zones
4–5
Programming Hardwired Zones
Each zone must be programmed into the system using the
∗
56 Zone Programming mode, or
∗
58 Expert Programming Mode, which assigns characteristics that define the way the system
responds to faults on that zone. Refer to
Section 15: Zone Response Type Definitions
and
Section 17: Zone Programming
for specific instructions on programming hardwired zones.
Checkout Procedure for Hardwired Zones
After installation and programming of all hardwired devices is completed, the security
system should be checked, as follows.
1.
Make certain that all devices and sensors connected to the hardwired zones are not in a
faulted state. Doors and windows with contacts should be closed, PIRs should be covered
(use a cloth to mask them temporarily if necessary).
2.
Plug in the AC transformer if you have not already done so.
3.
With all hardwired zones intact, the alpha keypad connected to the system should display:
✱✱✱✱
D I S A R M E D
✱✱✱✱
R E A D Y T O A R M
If the following is displayed,
D I S A R M E D P r e s s
✱
t o s h o w f a u l t s
press
[
✱
]
to display the faulted zone(s). Restore any faulted zone(s) as necessary (also
make sure that you have connected a 2000 ohm EOL resistor across the terminals of
unused zones).
When the
DISARMED...READY TO ARM
message is displayed, you can proceed to the
next step.
4.
Fault and then restore every contact or sensor on each zone individually to ensure that it
is being monitored by the system. Each time a zone is faulted, the keypad should display
the number of the faulted zone. When each zone is restored, the “READY TO ARM”
message should appear again.
Observe the keypad as each zone is faulted and restored.
When the proper displays appear on the keypad(s), the hardwired zones in the system are
functioning properly.
5.
Unplug the AC transformer.
Summary of Contents for Vista-20Bay
Page 2: ......
Page 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Page 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Page 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Page 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Page 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Page 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Page 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Page 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Page 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Page 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Page 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Page 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Page 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Page 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Page 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Page 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...