VISTA-20BAY Installation & Setup Guide
6–6
5800 Series Transmitters Table
Also refer to
Appendix A
for transmitter input loops/button locations.
Model
Description
Input Type and Special Notes
5801
Wireless Panic
Transmitter
Enroll as “3” for RF (supervised), or “4” for UR (unsupervised).
Unit has 4 pushbuttons, each with a unique input (loop) code.
Each pushbutton must be assigned to a zone
NOTE:
Input loop (button) No. 4 must always be used.
5802
5802CP
Pendant Belt Clip
(Personal Emergency)
Transmitters
Enroll as “5” for BR (button-type transmitter).
5802MN
5802MN2
Miniature Personal
Emergency Trans.
Enroll as “3” for RF (supervised), or “4” for UR (unsupervised).
Single pushbutton-type transmitter.
5804
5804BD
Wireless Key
Transmitter
Enroll as “5” for BR (button-type transmitter).
Has 4 pushbuttons, each with a unique input (loop) code.
Each pushbutton must be assigned to a zone.
NOTE:
All buttons must be assigned the same input type.
5806
5807
5808
5807L
5807LT
5807LST
5808LST
5809
Wireless Photoelectric
Smoke Detectors
Low-profile versions of
the Wireless Photo-
electric Smoke
detectors
HeatSensor, 135
º
Detector/Transmitter
Enroll as “3” for RF (supervised).
At the “INPUT S/N” prompt, fault the detector as follows:
1. On many detectors, you must press a special test switch (not test button)
to fault the
detector
(see detector’s instructions).
NOTE:
With some detectors, you must short two contacts to fault the
detector. Disengage the detector’s cover and swing it open. These
contacts are on the PC board near a blue jumper (see detector’s
instructions). Momentarily short these contacts with a small screwdriver.
2. The keypad beeps twice when the detector is faulted the first time.
Wait 6 to 8 seconds, then press and release the test switch (or
momentarily short the contacts) again. If the control has accepted the
input code, 3 beeps sound and the enrolled input (loop) number is
displayed.
5816
5816MN
5816
TEMP
Door/Window
Transmitter
Low Temp Sensor
Enroll as “3” for RF (supervised).
Has two unique input (loop) zones: one for a wired closed-circuit contact loop,
and the other for a built-in reed switch (used in conjunction with a magnet).
Either or both may be used.
5817
Multi-Point Universal
Transmitter
Enroll as “3” for RF (supervised).
Has three unique input (loop) codes: one for a DIP switch-set “Primary” contact
loop, and the others for two “Auxiliary” closed-circuit contact loops.
The “Primary” loop may be set for:
•
Repeating or Single Transmission
•
Normally Open or Normally Closed circuit
•
Slow or Fast Response
•
3-Minute or No Transmission Inhibit
DIP Switches:
Set all DIP switches to the OFF position when enrolling the
serial number.
NOTE:
All loops must be assigned the same input type.
5818
Recessed Magnetic
Contact Transmitter
Enroll as “3” for RF (supervised).
5819
5819
BRS
5819
WHS
Shock Processor
Transmitter
Enroll as “3” for RF (supervised).
Has three unique input (loop) zones: one for a wired closed-circuit contact loop,
one for use with inertia-type shock detectors (mounted externally), and one for a
built-in reed switch (used in conjunction with a magnet).
5849
5850
5852
Glassbreak
Detector/Transmitter
Enroll as “3” for RF (supervised).
5890
5890P1
PIR Detector/
Transmitter
Enroll as “3” for RF (supervised).
The cover must be on the unit when enrolling the serial number.
When “enrolling” a transmitter’s ID code(s), any PIR in the vicinity that is not being enrolled should
be covered with a cloth, tissue, etc. to prevent activation.
Summary of Contents for Vista-20Bay
Page 2: ......
Page 22: ...VISTA 20BAY Installation Setup Guide 3 4 ...
Page 28: ...VISTA 20BAY Installation Setup Guide 4 6 ...
Page 32: ...VISTA 20BAY Installation Setup Guide 5 4 ...
Page 40: ...VISTA 20BAY Installation Setup Guide 6 8 ...
Page 64: ...VISTA 20BAY Installation Setup Guide 14 4 ...
Page 68: ...VISTA 20BAY Installation Setup Guide 15 4 ...
Page 82: ...VISTA 20BAY Installation Setup Guide 16 14 ...
Page 92: ...VISTA 20BAY Installation Setup Guide 17 10 ...
Page 98: ...VISTA 20BAY Installation Setup Guide 18 6 ...
Page 100: ...VISTA 20BAY Installation Setup Guide 19 2 ...
Page 110: ...VISTA 20BAY Installation Setup Guide 22 4 ...
Page 116: ...VISTA 20BAY Installation Setup Guide 23 6 ...
Page 122: ...VISTA 20BAY Installation Setup Guide 25 4 NOTES ...
Page 128: ...VISTA 20BAY Installation Setup Guide A 2 ...
Page 130: ...VISTA 20BAY Installation Setup Guide B 2 ...
Page 138: ... 1 9 l N7526 4V1 5 00 SINCE 1946 BAY ALARM 925 Ygnacio Valley Road Walnut Creek CA 94596 ...