ScreenPRO-II Controller • User’s Guide
273
`K==réÖê~ÇáåÖ=pçÑíï~êÉ
Serial Upgrade Method
9.
To troubleshoot the serial connection:
a.
If the
DCD
and
CTS
status lights are green, re-check the communication
settings in the loader, and verify that the COM port and Baud Rate
settings are correct.
b.
To verify ScreenPRO-II Controller communication settings, press
{
HOME
} >
MISC
> {
CONSL
} to display the
Console Port Setup Menu
.
c.
Verify the following settings:
•
Baud rate = 115200
•
Data Bits = 8
•
Parity = None
•
Stop Bits = 1
d.
Repeat steps
7
and
8
above, then re-check the status lights.
e.
With communication status OK, continue with step
10
.
10.
To upload files to ScreenPRO-II Controller, click "
Open script file to read and
upload
."
11.
In the dialog, select "
Complete_Load.sld
" and click
Open
. The ScreenPRO-II
Controller menu should immediately display the "
System in LOADER MODE
"
message.
12.
It takes several minutes to load the flash memory. When complete, the Flash
Loader utility displays the “
Upload Complete
” message. Click
OK
to continue.
13.
Cycle power on the ScreenPRO-II Controller, and exit the Flash Loader utility.
14.
On ScreenPRO-II Controller, perform a factory reset. In Chapter 5, refer to the
“
Return to Factory Default
” section on page 189 for instructions.
15.
On the ScreenPRO-II Controller, verify that the new software has been loaded
correctly. Press {
HOME
} >
SYSTEM
> {
SW VER
} to display the
Software
Version Menu
.
This completes the software upgrade procedure via serial communications.
Summary of Contents for ScreenPRO-II
Page 1: ...r d p molJff Manual 26 0505000 00 Revision A...
Page 14: ...14 ScreenPRO II Controller User s Guide Table of Contents...
Page 52: ...52 ScreenPRO II Controller User s Guide 2 Hardware Orientation Front Panel Sections...
Page 214: ...214 ScreenPRO II Controller User s Guide 5 System Setup Backup to Flash Memory Card...
Page 266: ...266 ScreenPRO II Controller User s Guide K p ScreenPRO II Input and Output Resolutions...