15
2.3.5
Single phase connection to package size A or B
Location
Connector X1, single or 2-part connector
Part number
MD
1
A...
MD
2
A...
Input voltage
115VAC, 1
φ
line to neutral
230VAC, 1
φ
line to neutral
Range
97-125VAC
220-250VAC
Note:
For single phase connection, the voltage ripple on the DC-bus is 25Vp-p for 5A (the peak
current for a 2.5A MintDrive) and 50Vp-p for 10A (the peak current for a 5A MintDrive).
This can limit the maximum speed of the motor.
Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm).
The threaded holes in the top and bottom of the enclosure are for cable clamps (provided).
The holes are threaded for M4 bolts no longer than 0.47” (12mm) in length. Longer bolts
may short circuit the electrical components inside the MintDrive.
2.3.6
Single phase connection to package size C
Location
Connector X1, single or 2-part connector
Part number
MD
1
A...
MD
2
A...
Input voltage
115VAC, 1
φ
line to neutral
230VAC, 1
φ
line to neutral
Range
97-125VAC
220-250VAC
Note:
For single phase connection, the voltage ripple on the DC-bus is 25Vp-p for 5A (the peak
current for a 2.5A MintDrive) and 50Vp-p for 10A (the peak current for a 5A MintDrive). This
can limit the maximum speed of the motor.
Tightening torque for terminal block connections is 4.4~5.3 lbin (0.5~0.6Nm).
The threaded holes in the top and bottom of the enclosure are for cable clamps (provided).
The holes are threaded for M4 bolts no longer than 0.47” (12mm) in length. Longer bolts
may short circuit the electrical components inside the MintDrive.
L
N
E
L
N
E
or
Earth stud
Summary of Contents for MintDrive
Page 2: ...MN1274 06 2001 Installation Manual Installation Manual...
Page 3: ......
Page 13: ...xii...
Page 56: ...43 Figure 22 Auxiliary encoder circuit...
Page 91: ...78...
Page 97: ...84...
Page 109: ...96...
Page 111: ...98 Figure A 1 MintDrive Closed Loop System Motor Speed Filter 16 Sample Filter...
Page 119: ...106...
Page 141: ...128...
Page 147: ...134...
Page 154: ......