13
L
N
Fuse
Connection
L
N
L1
L2
Earth
MintDrive
Circuit breaker and fuse not supplied.
For CE Compliance, see Appendix C.
Circuit
Breaker
L3
PE
L1
L2
Figure 5 - Circuit breaker and fuse, single phase, package size C
L1
Fuse
Connection
L1
L2
L1
L2
Earth
MintDrive
Circuit breaker and fuse not supplied.
For CE Compliance, see Appendix C.
Circuit
Breaker
L3
PE
L3
L2
L3
L1
L2
L3
Figure 6 - Circuit breaker and fuse, three phase, package size C
Note:
Metal conduit or shielded cable should be used. Connect conduits so the use of a Reactor
or RC Device does not interrupt EMI/RFI shielding. If local codes do not specify different
regulations, use the same gauge wire for Earth ground as is used for L and N.
Connect earth to the backplane of the enclosure.