6. Click
Next >
.
The Axis Configuration Test Select frame provides two options.
Click
PERFORM AXES CONFIGURATION TESTS
.
The axis configuration tests allows MCT to tune the MintDrive
for use with the attached motor.
7. Using the drop-down boxes, select the
exact
motor
type. This information can be found stamped into the
label attached to the motor.
Important Note
:
The following axis configuration tests must be
performed
with
the
motor
mechanically
disconnected from other machinery. The tests will
cause movement of the motor, so ensure that it is
safe for the motor to operate.
If it is safe for the motor to rotate, click
Coarse Tune Motor Parameters
.
Click
OK
to confirm that you wish to begin the tests. MCT will begin the motor tests.
8. For the final test, the load should be connected to the motor.
Ensure that it is safe for the motor to operate when connected to the load.
If it is safe for the motor to operate, click
OK
. MCT will perform the final test.
9. Click
Next >
to continue with the tuning process.
Note:
If an error occurs during any of the tests, an error number will appear on the error button at
the top of the window:
Click the button to see details of the error. When you have fixed the error, click
Clear Errors
and then
Coarse Tune Motor Parameters
to restart the tests.
Summary of Contents for MintDrive
Page 2: ...MN1274 06 2001 Installation Manual Installation Manual...
Page 3: ......
Page 13: ...xii...
Page 56: ...43 Figure 22 Auxiliary encoder circuit...
Page 91: ...78...
Page 97: ...84...
Page 109: ...96...
Page 111: ...98 Figure A 1 MintDrive Closed Loop System Motor Speed Filter 16 Sample Filter...
Page 119: ...106...
Page 141: ...128...
Page 147: ...134...
Page 154: ......