88
Problem
Check
The message
Lost User
Data: Defaulting to
Factory settings -
please wait...
is shown at
power-up.
If this message is followed by
You must now re-tune your
motor
retune the MintDrive by either re-entering the gain settings
set earlier or by following the tuning setup (see section 4.2 on
page 51).
If this message is followed by
Failed to automatically
reset Factory settings.
power-cycle the MintDrive.
If the same message re-appears or the Ready LED stays red,
contact Baldor Technical Support. Otherwise, retune the MintDrive
by either re-entering the gain settings set earlier or by following the
tuning setup (see section 4.2 on page 51).
If this message is followed by
Factory settings have been
reset, but failed to clear error flag. Try
clearing the error manually using CANCEL.
type
CANCEL
. and power-cycle the MintDrive. If the same message
re-appears or the Ready LED stays red, contact Baldor Technical
Support. Otherwise, retune the MintDrive by either re-entering the
gain settings set earlier or by following the tuning setup
(see section 4.2 on page 51).
The message
Initialization Error
is
shown at power-up.
Contact Baldor Technical Support.
The message
Fatal
Initialization Error
is
shown at power-up.
Contact Baldor Technical Support.
The message
Processor
Reset Code =
xx
is shown at
power-up.
If new firmware has just been downloaded this message may be
ignored.
If the MintDrive has been power-cycled, power-cycle the MintDrive
again. If the problem persists contact Baldor Technical Support.
If the firmware just reset without the unit being power-cycled,
contact Baldor Technical Support.
Summary of Contents for MintDrive
Page 2: ...MN1274 06 2001 Installation Manual Installation Manual...
Page 3: ......
Page 13: ...xii...
Page 56: ...43 Figure 22 Auxiliary encoder circuit...
Page 91: ...78...
Page 97: ...84...
Page 109: ...96...
Page 111: ...98 Figure A 1 MintDrive Closed Loop System Motor Speed Filter 16 Sample Filter...
Page 119: ...106...
Page 141: ...128...
Page 147: ...134...
Page 154: ......