Figure 10-35 ZOZX
The figure is zOzx type. The first point requires for the calibration is the origin of the coordinate system.
The second point is any point on the positive of the Z-axis, and the third point is formed at any point
within the first quadrant of the zOx plane. The angle formed by the three points is an acute angle.
Figure 10-36 ZOZY
The figure is zOzy type. The first point requires for the calibration is the origin of the coordinate system.
The second point is any point on the positive of the Z-axis, and the third point is formed at any point
within the first quadrant of the zOy plane. The angle formed by the three points is an acute angle.
During the calibration process, select the type of the coordinate system to be calibrated via Coord Type
firstly. Then, select the Calibration Mode mode, select Point1, click Set Point, enter teaching interface, and
calibrate the coordinate system origin. Use the same method to calibrate Point2 and Point3. Enter the name
of the coordinate system and click the Add button to save the coordinate system parameters.
➢
When modifying the coordinate system, first select the coordinate system on the list, and click
Calibration Mode, then you can modify Point1 to Point3,
➢
Coordinate system name can also be modified, after setting up, click the Modify button, and save the
modified parameters.
➢
When you delete a coordinate system, select the coordinate system on the list and click the Delete
button. The coordinate system is removed.
➢
The Clear button function clears the calibration results from Point1 to Point3 in the Calibration Mode.
➢
Display the Mode function is to display the value of the three waypoints of the calibrated coordinate
system. After a coordinate system is selected on the list, it automatically enters the Display Mode.
Clicking Point1 to Point3, the three waypoints used to calibrate the coordinate system are displayed in
the simulation interface.
➢
Move Here function is to move to a waypoint, the specific operation is in the Calibration Mode mode,
Summary of Contents for AUBO-i10
Page 1: ...USER MANUAL AUBO i10 CB4 Please read this manual carefully before using the product...
Page 2: ......
Page 10: ...V4 5 2015 2019 AUBO All rights reserved vi...
Page 26: ...V4 5 2015 2019 AUBO All rights reserved 22...
Page 44: ...V4 5 2015 2019 AUBO All rights reserved 40...
Page 56: ...V4 5 2015 2019 AUBO All rights reserved 52...
Page 87: ...V4 5 2015 2019 AUBO All rights reserved 83...
Page 127: ...V4 5 2015 2019 AUBO All rights reserved 123...
Page 161: ...V4 5 2015 2019 AUBO All rights reserved 157 Figure 11 43 script file editor...
Page 179: ......