Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
62
7.5 System Parameters
The system parameters, as shown in Fig 7.5, are related with the precision of driver shaft
of the cutting machine, coordinate axis, increase/decrease of rate and little arc processing
limited parameter.
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
Horizontal Axis Pulse
125.000
n/mm
Vertical Axis Pulse
125.000
n/mm
Max cutting speed
2000.000
mmpm
Max G00 speed
6000.000
mmpm
Max Manual speed
3000.000
mmpm
Small arc limit
500.000
mmpm
Limit speed below radius
0.00
mm
Flame adjust time
0.40
s
Plasma adjust time
0.30
s
Emergency stop time
0.08
s
Start speed
250.000
mm
Max +X
100000.000
mm
Max +Y
100000.000
mm
Min -X
-100000.000
mm
Min -Y
-100000.000
mm
F4 Powder
Fig 7.5 System Parameters
Horizontal Axis Pulse: The number of pulse that system needs to generate when the
machine move1mm towards X axis, maintaining 3 digits at most after decimal point.
Vertical Axis Pulse: The number of pulse that system needs to generate when the
machine move 1mm towards Y axis , maintaining 3 digits at most after decimal point.
Max Cutting Speed: the maximum cutting speed, unit is mm./m.
Max G00 speed: the allowable maximum speed when cutting tips idling.
Small Arc Limit: Maximum speed at cutting a small arc.