65
In the interface shown in Fig 7.7, after pressing Enter, the parameters will automatically be
saved in the root folder of flash disk, the file name is F2300.DAT
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
Horizontal Axis Pulse
125.000
n/mm
Vertical Axis Pulse
125.000
n/mm
Max cutting speed
2000.000
mmpm
Max G00 speed
6000.000
mmpm
Max Manual speed
3000.000
mmpm
Small arc limit
500.000
mmpm
Limit speed below radius
0.00
mm
Flame adjust time
0.40
s
Plasma adjust time
0.30
s
Emergency stop time
0.08
s
Start speed
250.000
mm
Max +X
100000.000
mm
Max +Y
100000.000
mm
Min -X
-100000.000
mm
Min -Y
-100000.000
mm
F4 Powder
Sure to export Parameter?
Fig 7.7 Parameter export
7.8 Save Parameters
After parameter modification, press
【
F8
】
to save, shown in Figure 7.8