Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
45
After inputting the fixed length, press ENTER. Press any direction key and then release, the
system will move the fixed length toward the direction, in the process of moving, when any
direction key or stop key is pressed, the system will stop moving.
5.4 Breakpoint Recovery
To guarantee that the breakpoint could work correctly, you need to satisfy the following
conditions:
1)
When the system is paused, the system will automatically regard the paused point as the
current breakpoint and remember it.
2)
In the process of incising, when power is off, the system will regard the power-off point as
the breakpoint and remember it.
When you need to process after the breakpoint, after the system powers on, don’t move
the torch, press F7 in the main interface to enter the manual function interface, then press F7 to
recover the breakpoint. After recovering it, if the torch hadn’t been moved and is on the position
when the power is off, press START keyboard, the system will process directly.
After the breakpoint is recovered, if the position is off from the original one, you could move
the torch to the original point manually, or realizing it through choosing rows or numbers. (Please
refer to chapter 4.6 Row and number Selection).
The method is: choose stopping incising, move the torch to the original point manually,
choose the nearest row through choosing the row selection(or number selection), press
“START”, then the system will show in Fig 5.3: