number unit is s.
Pierce 3 time: Perforation time with high pressure fuel gas. Enter any positive
number ,unit is s.
Exhaust Time: The delay of turned off oxygen gas to open the exhaust. Enter any
positive number ,unit is s.
Torch Up Time: When oxygen gas is turned off, the time for the torch to lift up. Enter
any positive number ,unit is s.
Torch Down Time: When oxygen gas is turned off , the time for the torch to put down.
Enter any positive number ,unit is s.
Pierce Up Time: Time for the torch to lift up during perforating. The difference
between Torch Up Time and Pierce Up Time is that: Torch Up Time means the time
that the torch needs to lift up when it needs to move to another place after the
current cutting is over; while the.
Pierce Up Time: means the time that the torch needs to lift up after preheating in
the fixed cycle of perforation.
Pierce Down Time: Time for the torch to put down in the perforation. The difference
between Torch Down Time and Pierce Down Time is that: Torch Down Time means
the time that the torch needs to put down before preheating; while the Pierce Down
Time means the time that the torch needs to put down after finishing Torch Up Time
and opening cutting oxygen in the fixed cycle of perforation.
THC Adjustment: According to the user device configuration, choose whether or
not to use high adjustment box.
7.3 Plasma Parameters
As shown in the fig 7.3, these are Plasma Parameters, which are related with the precision
of transmission shaft of the machine.