Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
59
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
DelayBeforeArc
0.00
s
Pierce time
0.00
s
Torch up time
2.00
s
Arcing check time
15.00
s
Position check time
0.00
s
Position up time
0.00
s
Speed to lock THC
95.00
mmpm%
Distance to lock THC
5.00
mm
Lose arc delay
0.00
s
Watch arc enable
No
<->
F4 Powder
Fig 7.3 plasma parameters
Arc time
:
Before the arc starting, the system time to wait. At this point, all output I /O
are turned off. Enter any positive number ,unit is s.
Pierce time: Perforation time. Enter any positive number ,unit is s.
Torch Up Time: When arc press is turned off, the time for the torch to lift up. Enter any
positive number, unit is s.
Arcing Check Time: Enter any positive number, unit is s. If not detected any feedback
signal of success arc starting within the detection time, the system prompts an error
message and terminates the current work of cutting, according memory breakpoints to
withdraw from the program.
Position check Time: Enter any positive number, unit is s. Delay time of the success of
position check.