Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
64
1. The parameters exported from the incising machine control system( refer to 7.7
Parameter Export) should satisfy the specified format. The file format is F2300.DAT
2. The file should be stored under the root folder of flash disk which is connected to the
USB interface.
When the above condition is satisfied, in the Fig 7.6, press Enter to confirm, and then you
could import the backup parameters to the system.
F1 Common
F2 Flame
F3 Plasma
F5 System
F6 Import F7 Export
F8 Save
Horizontal Axis Pulse
125.000
n/mm
Vertical Axis Pulse
125.000
n/mm
Max cutting speed
2000.000
mmpm
Max G00 speed
6000.000
mmpm
Max Manual speed
3000.000
mmpm
Small arc limit
500.000
mmpm
Limit speed below radius
0.00
mm
Flame adjust time
0.40
s
Plasma adjust time
0.30
s
Emergency stop time
0.08
s
Start speed
250.000
mm
Max +X
100000.000
mm
Max +Y
100000.000
mm
Min -X
-100000.000
mm
Min -Y
-100000.000
mm
F4 Powder
Sure to import Parameter?
Parameter file is F2300D.DAT
Fig 7.6 Parameter import
7.7 Parameter Export
After the parameter configuration is over, press F7 in the parameter configuration interface
to export the parameters, you should connect the flash disk to the USB interface before
exporting.