Service Support Spirit
Unique Solution
WWW.ARCBRO.COM
73
8.7.1 Parameter Backup and Restore
Parameter Backup: The process of parameter backup is, in the main interface press
F5(System Diagnosis), F8( System Definition), F2(Parameter Backup). The system will need
code, after inputting the code “1396”, press Enter, the system will import the default parameters.
In the following process, if the parameters is modified or some of them is broken, reset the
parameters.
Warning: after installing and debugging the complete equipment, equipment manufacturer
please backup the parameters.
Parameter Reset: The process of reset the parameters is, press F5(System Diagnosis) in
the main interface, F8(System Definition), F1(Parameter Reset).
Warning: After resetting successfully, please restart the system.
8.7.2 Input Definition
The controller could change the IO definition, including changing the order of IO number,
the type of IO( normally open or closed) according to the user’s need. In the system custom
definition interface, press
【
F3
】
to enter the definition interface, press
【
F1
】
to enter the input
definition interface. As shown in fig 8.8.
F1 Input
F2 Output
F8 Save
definition of input
forward limit
02
back limit 15
left limit 14
right limit 01
emergency stop 03
arcing feedback 04
Position detect 05
Plasma Collision 06
Move up input 09
Move down input 10
Move left input 07
Move right input 08
Acceleration input 16
Deacceleration input 17
Torch up input 18
Torch down input
19
F3 Axes
F4 Motor
Port Type
Port Type
Port- press PgUp/PgDn Type-press Enter
F5 Option
Fig 8.8 input definition