On a Windows PC the driver can be installed automatically over Windows Update, or it can be downloaded
manually. The MMI module can then be accessed directly from a web browser, using the IP address
169.254.254.254
.
All MMI functionality is supported over this interface.
14.10.2
R
ESETTING
IP
ADDRESS WITH
DIP
SWITCH
It is possible to restore to the factory-configured IP address on the MMI module. This can be useful if the
software-configured IP address is lost. The restore is done by setting DIP switch
2
to
‘
ON
’
on the MMI
card. When the setting has been applied, the MMI will be configured according to the tables below regardless of
what is stored in memory.
The default IP settings are:
IP Address
192.168.1.100
Subnet Mask
255.255.255.0
Default Gateway
192.168.1.1
After setting the DIP switch the MMI card has to be rebooted. The factory default IP settings will be active as long
as the setting is present. While the DIP switch on, all IP parameters in memory can be changed and saved via the
web interface. Once the DIP switch is changed back to OFF and the card is rebooted, the IP settings in memory
will be activated.
In order to remove the module, the following procedure must be followed:
1.
Loosen the thumb screws for the fan assembly and remove the fans
2.
Loosen the thumb screws on the MMI module
3.
Press on the Switch-MMI module to come out little.
4.
Take out complete Switch-MMI module.
5.
Set DIP Switch 2 = ON
6.
Replace both MMI and fan assembly
14.11
R
ESTORING THE
D
EFAULT
CLI
P
ASSWORD
It is possible to restore to default SSH/CLI password for the MMI Module. The restore is done by setting dip
switch 5 to ON on the MMI card.