The following information is displayed:
IP
Backup ECMG’s IP address
Port
Backup ECMG’s TCP port
Channel
SimulCrypt channel ID for the Backup ECMG
CAS Sub Id
CA vendor specific Sub ID
12.7.3
M
ANUAL
S
WITCHING
Based on the figure above, click
Switch
. The
State
value (Running, Sleeping) should change accordingly.
12.7.4
EMMG
R
EDUNDANCY
When defining the EMMG, it is possible to state its IP address, otherwise known as
IP Filter
. Specifying an IP filter
prevents unknown EMMGs from connecting to the Scrambler module.
However, it is not compulsory to add this
IP Filter
. Using the value
0.0.0.0
ensures that the EMMG connection
will not validate the Source IP address (of the EMMG). In addition, multiple sources may connect to the same
listening port, but not concurrently.
If a Main and a Backup EMMG are present in the system, the first EMMG to connect will be the active one. A
connection from the second unit will be rejected as long as an EMMG is currently active.
It is not possible to manually switch the EMMGs as this connection controlled by the
EMMG itself.