APPEAR AS
Confidential
304/352
12.2.3
C
ONFIGURING
M
ODULES FOR
I
NTERNAL
R
EDUNDANCY
Configuring internal redundancy is done by selecting Redundancy
→
Internal in the
Navigation Pane
. This will
load the configuration page displayed below.
There are three sections on the Internal Redundancy configuration page:
This MMI card
–
displays the status of the MMI module in the chassis. This section is used as an indicator for MMI
correlation. MMI correlation is needed to get rid of the card missing alarms on the spare MMI module. The status
of the MMI module depends on which backplane it is logged in to.
Twin MMI card
–
displays the status of the Twin MMI card linked to this chassis, if there is one. The IP address of
the redundant MMI module is used to notify the internal redundancy GUI about the module. This other MMI
module is referred to as
Twin MMI
. Once a
Twin MMI
is added, both MMI modules will exchange their module
list; all other configuration must be done separately on each MMI module.
Internal redundancy supported cards
–
displays a list of modules on which internal redundancy is supported,
along with the service name (or number of services for QAM output modules), status, and switching delay. If
internal redundancy is not enabled, the service name value is
off
.
An alarm with the message
Unable to communicate with TWIN MMI i
s generated whenever connection breaks
between MMI Input cards.
Enable
The check box must be checked to enable internal redundancy on the module.
Each module can be configured at any time no matter which backplane it is
logged in to.
Slot
The slot in which the module has been installed
Type
The type of module on which internal redundancy is being enabled