296/352
Figure 11.12 - EPG Node
If multiple services are available for the matching criteria, a drop down box is displayed under EIT Source; pick the
best course of actionThe user must configure the
EIT Source
for the outgoing service being configured. The
following options will be presented in the corresponding drop-down menu:
AutoAuto
Corresponds to the value chosen in the
EPG
Setup
node, under
Matching Criteria
. If
multiple sources match, it will select one according to the
Multiple Match Action
setting..
Stop
Ensures that no schedule information is transmitted from this service. If no drop down
box is displayed, it means that there is only
one
source available based on the matching
criteria.