Mandatory Safety Instructions
1
The equipment must be installed by a qualified person.
2
For that equipment with grounding, connect the driver before connecting the power cord.
So opposite the power cord must be removed before removing the driver of the ground.
3
The equipment must be installed in a restricted area where:
•
Only qualified technicians have access or who know the most important safety
measures.
•
Access to the area where the devices are installed will be using a tool, lock and key,
or any other safety device, and in addition the site will be controlled by an
authorized person.
警告:接続ケーブルのプラグは、切断するためのものです。
電源プラグが常に手の届きやすい場所にくるように設置してください。
2.1.4
I
NSTALLATION
2.1.4.1
Power supply rating
The 4RU chassis is supplied with either a 100-240V AC 50/60 Hz power or -48V DC power. The 100-240V AC
50/60 Hz power supply is rated for maximum 300W, 400W or 800W
1
. The -48V DC power is rated for maximum
400W or 800W
2
. Figures 2.6. 2.7, 2.8, 2.9, 2.10, 2.11 and 2.12 below shows the power supply inlets.
The 1RU chassis is supplied with a 100-240V AC 50/60 Hz power rated for maximum 200W for product models
DC1100/1101, SC2100/101 and MC3100 /3101.
The 1Ru chassis, product model XC5100, is supplied with single or dual 100-240V AC, 47-63Hz , 400W power, or
with single or dual -48V DC, 500W power.
2.1.4.2
4RU chassis with 300 and 400W AC Power
The chassis can be hold two power supplies for redundancy and has independent power inlets for the two
supplies.
1