background image

O p e r a t i o n / R e f e r e n c e   G u i d e

T o u c h   P a n e l s

NXD/T-1200V

12" Modero

®

 Video

Wall/Flush Mount Touch Panel

(Composite/S-Video Support)

L a s t   R e v i s e d :   1 2 / 1 9 / 2 0 1 2

Summary of Contents for Modero NXD-1200V

Page 1: ...Operation Reference Guide Touch Panels NXD T 1200V 12 Modero Video Wall Flush Mount Touch Panel Composite S Video Support Last Revised 12 19 2012...

Page 2: ...ked on the outside of each box The RMA is valid for a 30 day period After the 30 day period the RMA will be cancelled Any shipments received not consistent with the RMA or after the RMA is cancelled w...

Page 3: ...PLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE AMX SOFTWARE THIS LIM ITED WARRANTY GIVES LICENSEE SPECIFIC LEGAL RIGHTS Any supplements or updates to the A...

Page 4: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...

Page 5: ...errites 12 NXA CFTP Compact Flash FG2116 2x 13 NXA PCI80211G Wireless Card FG2255 04 13 Product Specifications 14 Installation and Upgrade of the Internal NXT Components 15 Step 1 Remove the existing...

Page 6: ...NXD panel within a Conduit Box 34 Installing the NXD into drywall using Expansion Clips 35 Installing the NXD into a Flat Surface using 4 screws 38 Installing an NXD into an optional Rack Mount Kit N...

Page 7: ...61 Master Connection section NetLinx Master Ethernet IP Address URL Mode 62 Master Connection section NetLinx Master Ethernet IP Address Listen Mode 63 Master Connection section NetLinx Master Etherne...

Page 8: ...ted Setup Navigation Buttons 91 Protected Setup Page 92 G4 Web Control Page 94 Sensor Setup Page 95 Using the Automated Brightness Control feature DIM Mode 97 Password Setup Page 98 Calibration Page 9...

Page 9: ...T 115 BAU 115 BCB 115 BCF 116 BCT 116 BDO 116 BFB 117 BIM 117 BLN 117 BMC 118 BMF 119 BMI 121 BML 121 BMP 121 BNC 122 BNN 122 BNT 122 BOP 122 BOR 123 BOS 123 BPP 123 BRD 124 BSF 124 BSM 124 BSO 124 BV...

Page 10: ...BCB 134 BCF 135 BCT 135 BMP 136 BOP 136 BRD 137 BWW 137 FON 138 ICO 138 JSB 139 JSI 139 JST 140 TEC 140 TEF 141 TXT 141 Panel Runtime Operations 142 ABEEP 142 ADBEEP 142 AKB 142 AKEYB 142 AKEYP 142 A...

Page 11: ...150 Escape Sequences 151 DV 151 SY 151 IP 151 HN 151 MC 151 ID 151 PX 151 PY 151 ST 151 AC 151 AP 151 CC 151 CP 151 LC 151 LP 151 BX 151 BY 151 BN 151 Appendix 153 Text Formatting Codes for Bargraphs...

Page 12: ...viii 12 Modero Video NXD T 1200V Wall Flush Mount Touch Panel Table of Contents Troubleshooting 159 Overview 159...

Page 13: ...ivity for mouse and keyboard and antennas the use of a mini USB port for panel programming and a complete departure from the use of an ICSNet connector for communication These panels include a built i...

Page 14: ...8 bit Alpha channel transparency Contrast ratio 300 1 Display area HW 183 10 mm x 247 40 mm Display colors 256K 18 bit color depth Dot Pixel pitch 0 297 mm Screen resolution HV 800 x 600 pixels Video...

Page 15: ...ro Table Top Cable CA2250 50 provided with all NXT Table Top panels NXA AVB ETHERNET Breakout Box FG2254 10 Other AMX Equipment CB TP12 Conduit Wallbox FG031 10 CC USB Type A to Mini B 5 Wire programm...

Page 16: ...the Protected Setup page to save any changes and restart the panel 3 After the panel splash screen disappears If a USB mouse has been connected a mouse cursor appears on the panel screen and its loca...

Page 17: ...XA AVB Ethernet using a 12 VDC compliant power supply Certifications FCC Part 15 Class B CE and EN 60950 Features Accepts either Composite or S Video video capable panels only Provides audio distribut...

Page 18: ...tor 41 5063 Rack Mount Kit KA2250 40 with mounting bracket 62 2254 02 Other AMX Equipment AC RK Accessory RackMount Kit FG515 Modero Table Top Cable CA2250 50 FIG 4 Sample wiring configuration on vide...

Page 19: ...for each channel An example of this cable is to strip the ends of 2 RCA audio cables and insert them into their respective locations on the Audio In port Either a balanced and GND or unbalanced and G...

Page 20: ...carried over the wire The receiving equipment takes the voltage difference between the two wires as the input signal Interference will usually get added to both wires equally and so gets cancelled by...

Page 21: ...ncluded as part of installation kits accompanying your particular Modero panel Each of the following Installation Kits come with the appropriate number of CAT5 Suppression Ferrites These ferrites must...

Page 22: ...figuresprovide across sectionview FIG 11 andadescription FIG 12 oftheModeroTableTopCable Maximum Table Top Cable Lengths for Modero Panels Panel Sizes 7 Panel 10 Panel 12 Panel 15 Panel 17 Panel Setup...

Page 23: ...E INSULATION ELEMENT 2 1 PAIR 18 AWG STRANDED TNNED COPPER PVC INSULATION AND FOIL SHIELDED OVERALL PAPER BINDER AND FLEX PVC JACKET 9 PAIRS COMPOSITE CABLE CONSISTING OF ELEMENT 1 2 X 4 PAIRS 24 AWG...

Page 24: ...f the Black RJ 45 Audio Video cable into the groove along the inside of the enclosure 4 Snap the enclosure shut with the cable inside and you re done 5 Repeat this process again only when installing a...

Page 25: ...2 11g The NXA 80211G allows the end user to take advantage of larger bandwidth to utilize features such as wireless intercom Motion JPEG networked video and standard wireless Ethernet communication to...

Page 26: ...y configured for wireless communication These NXT panels are all factory installed with both the NXA 80211G wireless mini PCI and 2 antennas Optional to the following NXD panels NXD 1200V NXD 1200VG N...

Page 27: ...ing Screws NXA PCI80211G Specifications Cont Power Consumption 802 11b communication RX 300 mA TX 64 mA Sleep 12mA 802 11g communication RX 330 mA TX 575 mA Sleep 12mA Radio Data Rate 802 11g complian...

Page 28: ...it up and away from the base Step 2 Install the 802 11g mini PCI Wireless Card 1 Discharge any static electricity from your body by touching a grounded metal object 2 Locate the mini PCI card connecto...

Page 29: ...11G and hold it in place 7 Locate the terminal ends of the antennas and apply downward pressure to snap them onto their gold tipped counterparts on the mini PCI card FIG 20 Carefully push down on each...

Page 30: ...w CF memory card and firmly insert it into the slot opening with the arrow facing towards the pins until the contact pins are completely inside the flash card and it is then securely attached to the p...

Page 31: ...iginal locations so they can fit into their provided openings on the Battery Base 8 Grasp both the LCD and housing and then rotate the entire unit back onto a flat surface 9 Insert all connectors and...

Page 32: ...h Memory card NXD Complete the procedures outline within Step 3 Install the Compact Flash Memory Card upgrade section on page 17 and then continue with the following step FIG 23 Location of the securi...

Page 33: ...T BP Power Pack FIG 25 is a rechargeable Lithium Ion smart battery used to provide power to the NXT Modero panel through the NXA BASE B Battery Base This battery incorporates an on board battery life...

Page 34: ...NXT Modero Panel section on page 23 for more detailed installation and usage instructions Product Specifications FIG 26 NXA BASE B and NXT BP combo NXA BASE B Specifications Dimensions HWD 1 13 x 8 6...

Page 35: ...ce connectors between the panel male connector and base female connector FIG 28 4 Carefully place the Modero panel over the base alignment pegs FIG 28 and FIG 29 5 Gently apply downward pressure until...

Page 36: ...p the panel LCD base combo and gently rotate the unit back onto the base Installing an NXT BP into the NXA BASE B The battery base does not directly connect to a power supply but rather receives its p...

Page 37: ...AMX logo will appear indicating the panel is receiving power Charging the NXT BP batteries with the NXA BASE B 1 Follow the procedures from the previous sub section to attach the NXT touch panel to t...

Page 38: ...he power cord with plug into a power outlet that meets the requirements outlined in the Specifications section for the NXT CHG FIG 31 NXT CHG Kit consists of one NXT CHG charger and two NXT BP batteri...

Page 39: ...ing NXT CHG LED Indicator section on page 27 section for LED information Recalibrating the batteries The recalibration process increases the accuracy of the battery charge level Recalibration of the b...

Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...

Page 41: ...ving the pre existing back box and installing the new VESA back box Threading cables through the strain relief grommet opening in the rear plastic cover Finalizing the installation of the NXD with VES...

Page 42: ...e four pan head Housing Screws into their pre drilled holes along the edges of the MB TP12 back box FIG 34 and secure them using a grounded Phillips head screwdriver 4 Place the I O connector plate ba...

Page 43: ...ain relief grommet over the desired cable location 5 Firmly push the Strain Relief Grommet into the opening toward the inside until the rim is securely flush against the back of the rear plastic cover...

Page 44: ...unit to the rim of the rear plastic cover 9 Align a VESA mount connector purchased separately to the four 8 32 screw holes on the back of the rear plastic cover FIG 34 10 Insert the four provided 8 3...

Page 45: ...stud through the stud fastening holes located on the inside of the conduit box FIG 37 by using either nails or screws FIG 36 Installation of grommet into the rear plastic enclosure Rear plastic cover...

Page 46: ...ection on page 33 for detailed pre wall installation instructions Verify that all necessary cables have been threaded through the knockouts on the conduit box and the connections have been tested prio...

Page 47: ...eo wiring to their respective locations outside the conduit box on either the NXA AVB ETHERNET Breakout Box Ethernet port or NetLinx Master 10 Reconnect the terminal power connector on the 12 VDC comp...

Page 48: ...sh Mount Touch Panel 3 Remove the magnetic faceplate bezel A in FIG 40 from the main NXD unit B in FIG 40 by gripping the faceplate and pulling with gentle outward force FIG 39 NXD 1200V 12 inch Wall...

Page 49: ...installation 7 Disconnect the terminal end of the power cable from the connected power supply 8 Insert the four sets of drywall screws and expansion clips into the four oval notch locations along the...

Page 50: ...ted at the left and right sides of the NXD panel The most important thing to remember when mounting the NXD is that the outer frame Mounting Tabs must be installed flush against the mounting surface I...

Page 51: ...t until the Mounting Tabs of the NXD unit lie flush against the wall 9 Insert and secure the four 4 screws into their corresponding holes located along the sides of the NXD using a grounded Phillips h...

Page 52: ...Insert the main 12 inch Modero unit into an NXA RK12 FIG 43 7 Secure the panel to the NXA RK frame by first inserting and then tightening the four 4 40 screws provided Line up the four mounting holes...

Page 53: ...excessively doing so may strip the threads and damage the connector Wiring a power connection To use the 2 pin 3 5 mm mini Phoenix connector with a 12 VDC compliant power supply the incoming PWR and G...

Page 54: ...outs signals and pairing associated with the Ethernet connector Audio Video RJ 45 Pinout Information Pin Wire Color Function Polarity 1 Orange White Right Audio In 2 Orange Right Audio In 3 Green Whit...

Page 55: ...the AMX Splash Screen is replaced by the Initial Panel Page FIG 46 Calibrating the Modero Panel 1 Press and hold the grey Front Setup Access button FIG 47 for 6 seconds passing over the Setup page to...

Page 56: ...tected Setup page FIG 48 Touch Panel Calibration Screens The request to touch the crosshairs is the first on screen message Calibration successful is the second on screen message that appears On scree...

Page 57: ...Press Done to close the keypad assign the number and return to the Protected Setup page USB input devices must be plugged into the rear or side USB connectors before the G4 panel is powered up The pan...

Page 58: ...tinuing open NetLinx Studio 2 x This program assists in developing a System Number Master IP URL and Master Port number Refer to your NetLinx Master s instruction manuals for more information FIG 52 S...

Page 59: ...ere previous versions of these files already exist This can occur if you have previously installed released versions of NetLinx Studio and TPDesign4 If you are prompted to replace the AXBLAN INF file...

Page 60: ...he unit displays the first panel page THEN insert the mini USB connector into the Program Port on the panel It may take a minute for the panel to detect the new connection and send a signal to the PC...

Page 61: ...nch the Device Manager dialog Within the Device Manager dialog the AMX USBLAN device appears under Network Adapters FIG 55 and has a unique name such as AMX USB LAN LINK 2 The number changes depending...

Page 62: ...ommunicate directly with a panel Everything else such as the Authentication is greyed out because you are not going through the Master s UI 7 Click the Edit Settings button on the Communications Setti...

Page 63: ...ni USB Program port on the touch panel and the PC This method of communication is used to transfer firmware KIT files and TPD4 touch panel files 1 Verify this direct USB connection Type A on the panel...

Page 64: ...ing the Wireless Settings assigned within the Wireless Settings page The WAP communication parameters must match those of the pre installed wireless interface card installed within the panel Wireless...

Page 65: ...e cycles to DHCP This action causes all fields in the IP Settings section other than Host Name to be greyed out 5 Press the optional Host Name field to open a Keyboard and enter the Host Name informat...

Page 66: ...The procedures outlined within the following sections use an NXA WAP200G and the target WAP Configuring the Modero s wireless card for unsecured access to a WAP200G 1 Power down the Modero unit and f...

Page 67: ...less Configuration page Since the code key generator on Modero panels use the same key generation formula all panels will generate identical keys for the same Passphrase The generators used on WAPs wi...

Page 68: ...panel and the Wireless Access Point have the same WEP Key to authenticate 9 Toggle the Encryption field FIG 60 until it reads WEP64 or WEP128 The 64 128 selection reflects the bit level of encryption...

Page 69: ...ing a Current Key generated either by your target WAP or another Modero panel within the WEP Keys section touch the Key button to launch the WEP Key keyboard FIG 62 enter the characters and press Done...

Page 70: ...n assigned to the target Master If you have previously established a wireless connection to the Internet you must still navigate to the System Settings page and configure the communication parameters...

Page 71: ...ne when compete Repeat this process for the Secondary DNS field 10 Press the Domain field to open a Keyboard enter the resolvable domain Address this is provided by your System Administrator and equat...

Page 72: ...press and hold the grey Front Setup Access button for 3 seconds to proceed to the Setup page 7 Select Protected Setup System Settings located on the lower left to open the System Settings page FIG 63...

Page 73: ...rough the Master s UI 7 Click the Edit Settings button on the Communications Settings dialog to open the Virtual NetLinx Master Settings dialog FIG 64 8 From within this dialog enter the System number...

Page 74: ...tion section NetLinx Master Ethernet IP Address URL Mode In this mode enter the System Number zero for an unknown System Number and the IP URL of the Master Master Port Number is defaulted to 1319 1 P...

Page 75: ...ection Mode until the choice cycles to the word Listen 4 Enter a username and password into their respective fields if the target Master has been previously secured 5 Select the OnLine Tree tab from t...

Page 76: ...for 3 seconds to open the Setup page 2 Press the Protected Setup button located on the lower left of the panel page to open the Protected Setup page and display an on screen keypad 3 Enter 1988 into...

Page 77: ...ssword keyboard enter a unique alpha numeric string to be assigned as the G4 Authentication session password associated with VNC web access of this panel 13 Press Done after you are finished assigning...

Page 78: ...ation Both HTTP and HTTPS Ports are enabled by default via the Manage System Server page If the Master has been previously configured for secured communication click OK to accept the AMX SSL certifica...

Page 79: ...within the secondary browser window 10 Enter the Web Control session password into the Session Password field FIG 70 This password was previously entered into the Web Control Password field within the...

Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...

Page 81: ...estart your machine 2 After the panel powers up press and hold the grey Front Setup Access button for 3 seconds to continue with the setup process and proceed to the Setup page 3 Select Protected Setu...

Page 82: ...he Virtual Master radio box from the Transport Connection Option section to indicate you are wanting to configure the PC to communicate directly with a panel Everything else such as the Authentication...

Page 83: ...ero panel value is 10001 5 If the panel firmware being used is not current download the latest Kit file by first logging in to www amx com and then navigate to Tech Center Firmware Files and from with...

Page 84: ...devices on your particular system 15 Confirm the panel has been properly updated to the correct firmware version Upgrading the Modero Firmware via an IP Address Before beginning with this section veri...

Page 85: ...r is initially responding online before establishing full communication 10 Click OK to close the current New TCP IP Settings dialog and return to the previous TCP IP Settings dialog where you must loc...

Page 86: ...can be set within the active AMX software applications such as NetLinx Studio TPD4 or IREdit 3 Press the red Master IP URL field to open a Keyboard and enter the NetLinx Master s IP Address obtained...

Page 87: ...ished 10 Click Send to begin the transfer The file transfer progress is indicated on the bottom right of the dialog FIG 77 11 Click Close after the panel reboots to return to the main program 12 Right...

Page 88: ...rey Front Setup Access button for 3 seconds to open the Setup page 3 Press the Battery Base button to open the Battery Base page FIG 79 Step 2 Upgrade the NXA BASE B firmware via USB 1 Complete the pr...

Page 89: ...ick Send to begin the transfer The file transfer progress is indicated on the bottom right of the dialog 12 As the panel is rebooting temporarily unplug the USB connector on the panel until the panel...

Page 90: ...tion between the PC and the Master verify the target panel appears in the OnLine Tree tab of the Workspace window The default Modero panel value is 10001 The NXA BASE B will not appear on the system l...

Page 91: ...stablishes a new connection to the Master and populates the System list with devices on your particular system 13 Press and hold the grey Front Setup Access button below the LCD for 3 seconds to acces...

Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...

Page 93: ...anel Information Page section on page 84 for more detailed information Time Adjustment Press the Time Adjustment button to access the Time Adjustment page where you can alter the time and date setting...

Page 94: ...tly secured target Master requiring a username and password Connection Status Displays whether the panel is communicating externally the encryption status of the communicating Master what connection t...

Page 95: ...DN buttons to increase decrease the time the panel can remain inactive before it flips to the preset page Range 0 240 minutes Use this button to set the timeout value to zero and disable the inactivi...

Page 96: ...y active touch panel page Connection Status icon This visual display of the connection status allows the user to have a current visual update of the panel s connection status regardless of what page i...

Page 97: ...imeout Sleep String Displays the sleep string used during a panel s sleep mode File System Displays the amount of Compact Flash memory available on the Modero panel RAM Displays the available RAM or E...

Page 98: ...the UP DN buttons to alter the second value range 0 59 Modero touch panels do not have an on board clock This page both receives and sets the time date of the NetLinx Master FIG 87 Volume configurati...

Page 99: ...w As an example Composite video is available via slot 1 because of the location of associated components Since these components are shared between the 1200V Series and VG Series panels it is an option...

Page 100: ...button sets the video settings to their default values indicated in this table The Undo Changes button disregards any changes made on the page since the last settings were saved The Save Settings but...

Page 101: ...se remaining on the batteries within the connected NXA BASE B Time Until Charged green indicates the amount of time remaining until the batteries installed within the connected NXA BASE B are fully ch...

Page 102: ...ected to the NXT Modero panel The Battery Level Port field indicates the port being used to report the combined charge status level back to the NetLinx Master on set in TPD4 The Battery Level field in...

Page 103: ...Setup Page section on page 95 for more detailed information Passwords Press the Passwords button to access the Passwords Setup page where you can specify up to five security passwords Default passwor...

Page 104: ...ous touch panel features The Function Show button enables the display of the channel port and channel code in the top left corner of the button the level port and level code in the bottom left corner...

Page 105: ...settings The following list allows the end user to specify which international keyboard is being connected to the Modero touch panel and then which characters should be reflected within the G4 Comput...

Page 106: ...e is currently active A Lock only appears on the icon if the panel has established a connection with a currently secured target Master requiring a username and password G4 Web Control Settings Sets th...

Page 107: ...trol Password Allows you to enter the G4 Authentication session password associated for VNC web access of this panel Web Control Port Allows you to enter the port value that the VNC Web Server runs on...

Page 108: ...Light Level bargraph displays a horizontal bargraph indicating the current value of the light level detected by the on board photo sensor This bargraph provides a visual representation of the numeric...

Page 109: ...l does not react to variations in the lighting conditions of a normal working environment Sensor Setup Page Elements Cont Dim Mode Minimum Brightness Allows you to alter the sensitivity of the Modero...

Page 110: ...Back Saves the changes and returns you to the previously active touch panel page Connection Status icon This visual display of the connection status allows the user to have a current visual update of...

Page 111: ...brate the actual touch panel again using the above procedures FIG 100 Wireless Settings page showing default values Wireless Settings Page Elements Back Saves the changes and returns you to the previo...

Page 112: ...panel before it is permitted to join the wireless network The SSID is the unique name used on the WAP and assigned to all panels in a wireless network that are communicating to the same target WAP It...

Page 113: ...s case sensitive Default Key Cycles through the four available WEP key identifiers in order to select a WEP key to use As the Default Key value is altered through selection the corresponding Current K...

Page 114: ...incorrect IP or encryption settings Signal Strength SNR Signal Noise Ratio is a measure of the relative strength of a wireless RF connection This indicator displays a description of the signal strengt...

Page 115: ...s of networks applications or acts as a go between two or more networks that use the same protocols Host Name Sets the host name of the panel Primary DNS Sets the address of the primary DNS server use...

Page 116: ...r the Master s communication signals The System Number and Master IP URL fields are red only Auto In this mode enter the System Number and a username password if applicable This mode is used when both...

Page 117: ...Range 1 256 0 All states for General buttons 1 Off state and 2 On state Level Range 1 600 Default level value 0 255 can be set up to 1 65535 Address port Range 1 100 These button assignments can only...

Page 118: ...ge to the named hide effect Syntax PHE popup page name hide effect name Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On hide effect name Refers to the popup e...

Page 119: ...the popup page Popup1 on the current page PPG Toggle a specific popup page on either a specified page or the current page If the page name is empty the current page is used see example 2 Toggling ref...

Page 120: ...ee example 2 If the popup page is already on do not re draw it This command works in the same way as the Show Popup command in TPDesign4 Syntax PPN popup page name page name Variable popup page name 1...

Page 121: ...t time Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On show effect time Given in 1 10ths of a second Example SEND_COMMAND Panel PST Popup1 50 Sets the Popup1...

Page 122: ...from one state to another On Off Example 2 SEND_COMMAND Panel PPOG Popup1 Toggles the popup page Popup1 on the current page from one state to another On Off PPON Activate a specific popup page to lau...

Page 123: ...t Cyan 0 255 255 37 Light Cyan 0 223 223 38 Cyan 0 191 191 39 Medium Cyan 0 159 159 40 Dark Cyan 0 127 127 41 Very Dark Cyan 0 95 95 42 Very Light Aqua 0 128 255 43 Light Aqua 0 112 223 44 Aqua 0 96 1...

Page 124: ...3 Grey13 34 34 34 84 Grey2 221 221 221 85 Grey11 68 68 68 86 Grey14 17 17 17 87 Black 0 0 0 255 TRANSPARENT 99 53 99 Default Font Styles and ID Numbers Font ID Font type Size Font ID Font type Size 1...

Page 125: ...tom Frame Menu Left Rounded 55 Diamond 15 Menu Left Rounded 65 Diamond 25 Menu Left Rounded 75 Diamond 35 Menu Left Rounded 85 Diamond 45 Menu Left Rounded 95 Menu Left Rounded 105 Menu Top Rounded 65...

Page 126: ...opup Menu Rounded Spacer Horizontal Window Style Popup Status Bar Menu Top Rounded 55 Button Commands ANI Run a button animation in 1 10 second Syntax ANI vt addr range start state end state time Vari...

Page 127: ...nicode characters must be entered in Hex format Example SEND_COMMAND Panel BAU 520 1 00770062 Appends Unicode text 00770062 to the button s OFF state BCB Set the border color to the specified color On...

Page 128: ...me without spaces number or R G B value RRGGBB or RRGGBBAA Syntax BCT vt addr range button states range color value Variable variable text address range 1 4000 button states range 1 256 for multi stat...

Page 129: ...ter types Example SEND_COMMAND Panel BIM 500 AAAAAAAAAA Sets the input mask to ten A characters that are required to either a letter or digit entry is required BLN Set the number of lines removed equa...

Page 130: ...source address 1 4000 source state 1 256 codes BM Picture Bitmap BR Border CB Border Color CF Fill Color CT Text Color EC Text effect color EF Text effect FT Font IC Icon JB Bitmap alignment JI Icon a...

Page 131: ...Set the icon using values of 01 9900 icon numbers are assigned in the TPDesign4 Resource Manager tab Slots section I icon 01 9900 0 clear Set the icon using values of 01 9900 icon numbers are assigned...

Page 132: ...on SF 1 or 0 Set the focus for text area button OP 0 255 Set the button opacity to either Invisible value 0 or Opaque value 255 OP 00 FF Set the button opacity to either Invisible value 00 or Opaque v...

Page 133: ...ress range 1 4000 button states range 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On state mask image Chameleon used Example SEND_COMMAND Panel BMI 530 1 2 newMac...

Page 134: ...ress range 1 4000 network port 1 65535 Example SEND_COMMAND Panel BNT 973 5000 Sets the TakeNote button network port to 5000 BOP Set the button opacity The button opacity can be specified as a decimal...

Page 135: ...ew Slot ID is set only if the specified slot is not the same as the current slot selected Passthru sets the passthru mode to On This is an optional parameter and ONLY passes data to the PC Syntax BOS...

Page 136: ...ocus to multiple buttons Only one variable text address can be in focus at a time Syntax BSF vt addr range selection value Variable variable text address range 1 4000 selection value Unselect 0 and se...

Page 137: ...fied address Syntax BVP vt addr range network password Variable variable text address range 1 4000 network password 1 50 ASCII characters Example SEND_COMMAND Panel BVP 500 PCLOCK Sets the password to...

Page 138: ...age ENA Enable or disable buttons with a set variable text range Syntax ENA vt addr range command value Variable variable text address range 1 4000 command value 0 disable 1 enable Example SEND_COMMAN...

Page 139: ...500 3 Inverts the joystick axis origin to the bottom right corner GLH Change the bargraph upper limit Syntax GLH vt addr range bargraph hi Variable variable text address range 1 4000 bargraph limit r...

Page 140: ...or value Refer to theRGB Values for all 88 Basic Colors table on page 110 Example SEND_COMMAND Panel GSC 500 12 Changes the bargraph or joystick slider color to Yellow GSN Change the bargraph slider n...

Page 141: ...ates for General buttons 1 Off state and 2 On state new text alignment Value of 1 9 corresponds to the following locations Example SEND_COMMAND Panel JSB 500 504 510 515 1 2 1 Sets the off on state pi...

Page 142: ...510 515 1 2 1 Sets the text alignment to the upper left corner for those buttons with variable text ranges of 500 504 510 515 MBT Set the Mouse Button mode On for the virtual PC Syntax MBT pass data V...

Page 143: ...l buttons 1 Off state and 2 On state color value Refer to theRGB Values for all 88 Basic Colors table on page 110 Example SEND_COMMAND Panel TEC 500 504 510 515 1 2 12 Sets the text effect color to Ve...

Page 144: ...ext For the UNI command UN and BMF command the Unicode text is sent as ASCII HEX nibbles Syntax UNI vt addr range button states range unicode text Variable variable text address range 1 4000 button st...

Page 145: ...Send_String 0 VALUE1 ITOA CUSTOM VALUE1 Text Effects Glow S Hard Drop Shadow 6 Glow M Hard Drop Shadow 7 Glow L Hard Drop Shadow 8 Glow X Soft Drop Shadow 1 with outline Outline S Soft Drop Shadow 2...

Page 146: ...e3 index of first character usually 1 or same as optional index string text the text from the button text length string encode button text length Button Query Commands BCB Get the current border color...

Page 147: ...lor information The result sent to the Master would be ButtonGet Id 529 Type 1012 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT FF8000FF TEXT LENGTH 9 BCT Get the current text color Syntax BCT vt addr range...

Page 148: ...BMP 529 1 Gets the button OFF state bitmap information The result sent to the Master would be ButtonGet Id 529 Type 1002 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT Buggs png TEXT LENGTH 9 BOP Get the over...

Page 149: ...border information The result sent to the Master would be ButtonGet Id 529 Type 1014 Flag 0 VALUE1 1 VALUE2 22 VALUE3 0 TEXT Double Bevel Raised L TEXT LENGTH 22 BWW Get the current word wrap flag sta...

Page 150: ...type index information The result sent to the Master would be ButtonGet Id 529 Type 1007 Flag 0 VALUE1 1 VALUE2 72 VALUE3 0 TEXT TEXT LENGTH 0 ICO Get the current icon index Syntax ICO vt addr range...

Page 151: ...ustification information The result sent to the Master would be ButtonGet Id 529 Type 1005 Flag 0 VALUE1 1 VALUE2 5 VALUE3 0 TEXT TEXT LENGTH 0 JSI Get the current icon justification Syntax JSI vt add...

Page 152: ...he Master would be ButtonGet Id 529 Type 1004 Flag 0 VALUE1 1 VALUE2 1 VALUE3 0 TEXT TEXT LENGTH 0 TEC Get the current text effect color Syntax TEC vt addr range button states range Variable variable...

Page 153: ...ttonGet Id 529 Type 1008 Flag 0 VALUE1 1 VALUE2 18 VALUE3 0 TEXT Hard Drop Shadow 3 TEXT LENGTH 18 TXT Get the current text information Syntax TXT vt addr range button states range optional index Vari...

Page 154: ...I characters Example SEND COMMAND Panel AKB Texas Enter State Pops up the Keyboard and initializes the text string Texas with prompt text Enter State AKEYB Pop up the keyboard icon and initialize the...

Page 155: ...45678 with prompt text ENTER PASSWORD AKR Remove keyboard or keypad that was displayed using AKEYB AKEYP PKEYP AKB AKP PKP EKP or TKP commands Syntax AKR Example SEND COMMAND Panel AKR Removes the Key...

Page 156: ...el PKEYP 123456789 Pops up the Keypad and initializes the text string 123456789 in PKP Present a private keypad Pops up the keypad icon and initializes the text string to that specified Keypad display...

Page 157: ...Enter Phone Number Pops up the Keypad and initializes the text string 999 222 1211 with prompt text Enter Phone Number TPAGEON Turn On page tracking This command turns On page tracking whereby when t...

Page 158: ...rd or Virtual keyboard SLT Send a command to a given slot These commands are directed at the video card subsystems Slot commands contain a series of name value pairs separated by commas These commands...

Page 159: ...r command Example SEND COMMAND Panel VKS 8 Sends out the keystroke backspace to the G4 application Embedded Codes Decimal numbers Hexidecimal values Virtual keystroke 8 08 Backspace 13 0D Enter 27 1B...

Page 160: ...lip password Variables page flip password 1 50 ASCII characters Example SEND COMMAND Panel PWD Main Sets the page flip password to Main PWD Set the page flip password Password level is required and mu...

Page 161: ...e preceded by a character any character contained in the URL must be escaped with a second character see example The file name field indicated by a F embedded code may contain special escape sequences...

Page 162: ...ncoded as 5F RSR Change the refresh rate for a given resource Syntax RSR resource name refresh rate Variable resource name 1 50 ASCII characters refresh rate Measured in seconds Example SEND_COMMAND P...

Page 163: ...When set the panel will first pull a list of files matching the given pattern from the specified FTP server and path The timestamps of the items in the list will be compared with the newest one being...

Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...

Page 165: ...ph Text Code Inputs Code Bargraph Multi State Bargraph P Display the current percentage of the bargraph derived from the Adjusted Level Value as it falls between the Range Values Display the current p...

Page 166: ...text area Suggest proper format with fixed characters Right to Left Required or Optional Change Force a Case Create multiple logical fields Specify range of characters number for each field Limit you...

Page 167: ...olders The character should display where you should enter a character The arrow keys will move between the characters and allow you to replace them The text entry code operates as if it is in the ove...

Page 168: ...and that the information resides on a host machine named www amx com The image on that host machine is given an assignment by the program name of company info home asp Active Server Page The exact me...

Page 169: ...replaces that code with a particular piece of panel button or state information For example http www amx com img asp device DV would become http www amx com img asp device 10001 Other used escape sequ...

Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...

Page 171: ...en established to the target Master or target Virtual Master Launch NetLinx Studio and configure the Master Connection communication settings for a Virtual Master Navigate to the System Settings page...

Page 172: ...and try again My NXT BP battery pack is blinking when I check the battery life indicator A blinking battery life LED indicates that there is less than 10 power charge remaining on the battery It is r...

Page 173: ...e Automatically Ping the Master Controller to ensure availability The pinging is to determine if the Master is available and to reply with a connection failure instantly if it is not Without using the...

Page 174: ...o send download the page Reboot the device then do your regular file or firmware download My NXA BASE B Battery Base isn t being recognized by the NXT touch panel The battery base CAN NOT be hot swapp...

Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...

Page 176: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...

Reviews: