Wireless Settings Page - Wireless Access Overview
IP Routing
The behavior of the wireless routing is largely dependent on the wired network interface. Although the panel can be
connected to two networks simultaneously it may only have one gateway. If the wired network was successfully set up
and a gateway was obtained; then the default route for all network traffic will be via the wired network. In the event that
the wired network was not configured, then the default route for all network traffic will be via the wireless network. The
wired network connection always takes priority.
As an example: Imagine a panel connected to two networks A & B.
A
is the wired network and
B
is the wireless
network. If the Master controller is on either of these networks then it will be reached. However if the Master controller
is on a different network,
C
, then determining which network interface (wired or wireless) that will be used is dependent
on the gateway.
Hot Swapping
Hot swapping is not an issue on these panels as the card is installed within the unit and cannot be removed without first
removing the housing.
In the case of DHCP, there must be a DHCP server accessible before the fields are populated.
Ethernet Communication from the panel can be direct (using an Ethernet cable) or indirect (through the NXA-
PCI80211G AMX Wireless Card (
FG2255-04
) communicating to a Wireless Access Point (WAP) such as the NXA-
WAP200G). In determining the Ethernet method of communication, the panel will always default first to the direct
Ethernet communication. If no direct connection is detected, the panel will first check to see if there is an installed
wireless interface card and then communicate to the WAP using the Wireless Settings assigned within the Wireless
Settings page. The WAP communication parameters must match those of the pre-installed wireless interface card
installed within the panel.
Wireless Access Points
are the cornerstone of any wireless network. A Wireless Access Point acts as a bridge
between a wired and wireless network. It aggregates the traffic from all the wireless clients and forwards it
down the network to the switch or router. One Wireless Access Point may be all you need. However, you
could need more Wireless Access Points depending on either how large your installation is, how it is laid out,
and how it is constructed.
Wireless Equivalent Privacy
(
WEP
) Security is a method by which WLANs protect wireless data streams.
A data stream encrypted with WEP can still be intercepted or eavesdropped upon, but the encryption makes
the data unintelligible to the interloper. The strength of WEP is measured by the length of the key used to
encrypt the data. The longer the key, the harder it is to crack.
802.11b implementations provided 40-bit and 104-bit WEP keys. This is known respectively as 64-bit and
128-bit WEP encryption. 64-bit is generally not regarded as adequate security protection. Both key lengths
are supported by the Modero product line. Whichever level of WEP you use, it's crucial to use identical
settings (CASE SENSITIVE)--the key length, and the key itself-- on all devices. Only devices with common
WEP settings will be able to communicate. Similarly, if one device has WEP enabled and another doesn't,
they won't be able to talk to each other.
Although the calculations required to encrypt data with WEP can impact the performance of your wireless
network, it's generally seen only when running benchmarks, and not large enough to be noticeable in the
course of normal network usage.
If the SSID (Network Name) and WEP fields have not previously been configured, the
Wireless Settings page will not work until the panel is rebooted.
Summary of Contents for Modero NXD-1200V
Page 40: ...Touch Panel Accessories 28 NXD T 1200V Wall Flush Mount Touch Panel...
Page 80: ...Configuring Communication 68 NXD T 1200V Wall Flush Mount Touch Panel...
Page 92: ...Upgrading Modero Firmware 80 NXD T 1200V Wall Flush Mount Touch Panel...
Page 164: ...Programming 152 NXD T 1200V Wall Flush Mount Touch Panel...
Page 170: ...Appendix 158 NXD T 1200V Wall Flush Mount Touch Panel...
Page 175: ...Troubleshooting 163 NXD T 1200V Wall Flush Mount Touch Panel...